B.2 Parameter Table Parameter List B OYMC TOEP C71060622-01-OY V1000 User Manual 385 Par.
Description Unit Default Settings E5-01 Motor Code − 120A 120B 120D 120E Voltage class Rated power − 200 Vac 5.5 kW 200 Vac 7.5 kW 200 Vac 11 kW 200 Vac 15 kW Rated speed min-1 1750 1750 1750 1750 E5-02 Motor rated power kW 5.5 7.5 11.0 15 E5-03 Motor rated current A 19.80 27.00 39.7 53.2 E5-04 Motor pole number – 6 6 6 6 E5-05 Motor winding resistance W 0.246 0.198 0.094 0.066 E5-06 d-axis inductance mH 4.86 4.15 3.40 2.65 E5-07 q-axis inductance mH 7.43 5.91 3.91 3.11 E5-09 Induction voltage constant 1 mVsec/rad 249.6 269.0 249.3 266.6 E5-24 Induction voltage constant 2 mV/min-1 0.0 0.0 0.0 0.0 E1-04 Maximum output frequency Hz 87.5 87.5 87.5 87.5 E1-05 Maximum output voltage V 190.0 190.0 190.0 190.0 E1-06 Base voltage Hz 87.5 87.5 87.5 87.5 E1-09 Minimum output frequency Hz 4.4 4.4 4.4 4.4 L3-24 Motor acceleration time s 0.083 0.077 0.084 0.102 n8-49 Pull-in current % –22.0 –17.3 –10.1 –10.3