omron — Parameters that Change with the Motor Code Selection

B.2 Parameter Table Table B.11 400 V, 1750 rpm Type Yaskawa SSR1 Series Motor 386 OYMC TOEP C71060622-01-OY V1000 User Manual Par.

Description Unit Default Settings E5-01 Motor Code − 1232 1233 1235 1236 1238 Voltage class Rated power − 400 Vac 0.4 kW 400 Vac 0.75 kW 400 Vac 1.5 kW 400 Vac 2.2 kW 400 Vac 3.7 kW Rated speed min-1 1750 1750 1750 1750 1750 E5-02 Motor rated power kW 0.4 0.75 1.5 2.2 3.7 E5-03 Motor rated current A 0.83 1.49 2.75 4.05 6.80 E5-04 Motor pole number – 6 6 6 6 6 E5-05 Motor winding resistance W 32.932 9.136 6.004 3.297 1.798 E5-06 d-axis inductance mH 219.36 92.08 68.32 40.39 32.93 E5-07 q-axis inductance mH 256.40 119.56 85.56 48.82 37.70 E5-09 Induction voltage constant 1 mVsec/rad 466.0 459.0 501.8 485.7 498.7 E5-24 Induction voltage constant 2 mV/min-1 0.0 0.0 0.0 0.0 0.0 E1-04 Maximum output frequency Hz 87.5 87.5 87.5 87.5 87.5 E1-05 Maximum output voltage V 380.0 380.0 380.0 380.0 380.0 E1-06 Base voltage Hz 87.5 87.5 87.5 87.5 87.5 E1-09 Minimum output frequency Hz 4.4 4.4 4.4 4.4 4.4 L3-24 Motor acceleration time s 0.092 0.076 0.051 0.066 0.075 n8-49 Pull-in current % –7.2 –10.7 –11.1 –8.9 –7.9