Текст документа
页 1
480W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power XTR-480 series User’s Manual (XTR-480-xx) (XTR-480-xxLA) (XTR-480-xxPI) T Y P E A P P R O V E D R P O D U C T SEMI F47 Voltage Sag Immunity Characteristics Verified Bauar Sicherheit od be egel ge ma wac g o s t gepruft (GL type) DNV.COM/AF DNV V E R I F I E D verify.U L.com V437575 1 UL61010 BS EN/EN62368-1 BS EN/EN61558-1 www. ID 2000000000 tuv.com IEC62368-1 IEC61558-1 AS/NZS61558-1 AS/NZS62368-1 IS13252 BS EN/EN61010-1 IEC61010-1 THOMAS SAMUEL THOMAS SAMUEL KC62368-1 GB4943 .
1 CNS15598-1 TPTC004 (By request) (By request) https://www.meanwell.com/serviceGTIN.aspx File Name:XTR-480-SPEC 2025-09-23
Стр. 1
页 2
480W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power XTR-480 series File Name:XTR-480-SPEC 2025-09-23 SPECIFICATION XTR-480-12 XTR-480-24 XTR-480-36 XTR-480-48 =Blank, LA, PI =Blank, GL OUTPUT DC VOLTAGE 12V 24V 36V 48V RATED CURRENT 30A 20A 13.3A 10A CURRENT RANGE 0 ~ 30A 0 ~ 20A 0 ~ 13.3A 0 ~ 10A RATED POWER 360W 480W 478.8W 480W CURRENT(5 sec.) PEAK POWER(5 sec.) RIPPLE & NOISE (max.) Note.2 CURRENT(5 sec.) 60A 40A 26.7A 20A POWER(5 sec.) 720W 960W 961W 960W 120mVp-p 120mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ.
RANGE 12 ~ 15V 24 ~ 29V 36 ~ 42V 48 ~ 55V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% SETUP, RISE TIME 800ms, 60ms/400Vac 600ms, 60ms/500Vac at full load HOLD UP TIME (Typ.) 20ms / 400Vac 20ms / 500Vac at full load INPUT VOLTAGE RANGE Note.4 NO LOAD POWER Remote Power OFF CONSUMPTION (Typ.) Remote Power ON Three-Phase 320 ~ 600Vac (Dual phase operation possible) 450 ~ 800Vdc Remote Power OFF 3.0W/400Vac 3.0W/400Vac 3.0W/400Vac 3.0W/400Vac Remote Power ON 5.0W/400Vac 5.0W/400Vac 5.0W/400Vac 5.0W/400Vac FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF≧0.9/400Vac PF≧0.88/500Vac at full load EFFICIENCY (Typ.) 93% 94% 94.5% 95.5% AC CURRENT (Typ.) 0.85A/400Vac 0.7A/500Vac INRUSH CURRENT (Typ.) COLD START 10A/500Vac LEAKAGE CURRENT PROTECTION OVERLOAD OVER VOLTAGE 105%~200% rated output power for more than 5 sec then constant current limiting without shutdown at rate current when Vo=30%~100% 15 ~ 18V 30 ~ 35V 43 ~ 50V 56 ~ 65V Protection type :
Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage or hiccup mode, recovers automatically after temperature goes down FUNCTION PARALLEL Up to 1920W (3+1), please refer to Function Manual for more details DC OK RELAY CONTACT Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5A resistive load REMOTE CONTROL Power ON : RC + ~ RC- open or keep 2~5Vdc Power OFF: RC + ~ RC- short or keep ENVIRONMENT WORKING TEMP. Note.5 -40 ~ +85℃ (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃) VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min.
each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
Стр. 2
页 3
480W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power XTR-480 series File Name:XTR-480-SPEC 2025-09-23 SPECIFICATION XTR-480-12 XTR-480-24 XTR-480-36 XTR-480-48 =Blank, LA, PI =Blank, GL SAFETY & EMC Note.7 SAFETY STANDARDS UL121201/CSA C22.2 NO.213.17 Class I, Div.
2 Group A, B, C, D Hazardous Locations T4; UL/CUL 61010-1/-2-201; TUV BS EN/EN 62368-1, BS EN IEC/EN IEC 61558-1/-2-16, BS EN/EN 61010-1/-2-201; CB IEC 62368-1, IEC 61558-1/2-16, IEC 61010-1/-2-201; RCM AS/NZS 62368-1,AS/NZS 61558-1/-2-16; BSMI CNS15598-1;CCC GB4943.1;EAC TPTC004 approved; Marine DNV (for GL type only) KC KC62368-1 and BIS IS13252 (Part 1):2010 certified, no stock ,contact sale for inquires OVER VOLTAGE CATEGORY Note.6 IEC/EN 61558-1/-2-16 (OVC Ⅲ, altitude up to 2000m ) IEC/EN/UL 61010 (OVC Ⅱ, altitude up to 5000m ) IEC/EN 62368-1 (OVC Ⅱ, altitude up to 5000m ) SAFETY EXTRA-LOW VOLTAGE(SELV) IEC/EN 61558-2-16 (SELV ) IEC/EN/UL 61010-2-201 (SELV ) IEC/EN 62368-1 (SELV/ ES1 ) WITHSTAND VOLTAGE I/P-O/P:4.87KVac I/P-FG:2.5KVac O/P-FG:0.5KVac O/P-DC OK:0.5KVac ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032(CISPR32) / BS EN/EN61204-3 / CNS15936 Class B Radiated BS EN/EN55032(CISPR32) / BS EN/EN61204-3 / CNS15936 Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 ----- BS EN/EN55035 , BS EN/EN61204-3 , BS EN/EN61000-6-2:2005 , BS EN/EN IEC61000-6-2:2019 Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact Radiated Field BS EN/EN61000-4-3 Level 3, 10V/m ; criteria A EFT / Burst BS EN/EN61000-4-4 Level 4, 4KV ; criteria A Surge BS EN/EN61000-4-5 Level 4, 2KV / Line-Line, Level 4, 4KV/ Line-Earth Conducted BS EN/EN61000-4-6 Level 3, 10V/m ; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m ; criteria A Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods> 95% interruptions 250 periods OTHERS MTBF 1267.7K hrs min.
Telcordia SR-332(Bellcore) ; 167.4K hrs min.
MIL-HDBK-217F (25℃) DIMENSION 63*125.2*125mm (W*H*D) PACKING 1.18Kg ; 8pcs/11.2Kg/1.28CUFT NOTE ℃ μμ ℃℃ ※:
Стр. 3
页 4
480W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power XTR-480 series Block Diagram PFC fosc : 65KHz PWM fosc : 60KHz DC OK EMI FILTER +Vo ORING FET -Vo Input RECTIFIERS & CIRCUIT PFC POWER SWITCHING O.L.P. UVP FG CONTROL PFC PWM CONTROL O.T.P. O.V.P. O.T.P.
PARALLEL P+ P- REMOTE CONTROL RC+ RC- Derating Curve 200 100 LOAD (%) 75 60 40 (VERTICAL) -30 -40 0 10 20 30 40 50 60 AMBIENT TEMPERATURE ( ) 70 85 Output derating VS input voltage 100 Three phase operation 90 85 80 LOAD (%) 60 70 50 40 340 320 380 420 440 460 480 500 400 530 600 INPUT VOLTAGE (V) 60Hz File Name:XTR-480-SPEC 2025-09-23 RECTIFIERS & FILTER DETECTION CIRCUIT Please refer to Function Manual of peak power Three phase operation Three phase operation Dual phase operation Dual
Стр. 4