hp Color 9850mfp FIXING 9.3 Replacing the fixing upper heater lamps 1 and 2 A. Periodically replaced parts/cycle • Fixing upper lamp 1 (L2): Every 2,500,000 cop- ies • Fixing upper lamp 2 (L3): Every 2,500,000 cop- ies B. Procedure 1. Remove the fixing unit. 2. Remove 2 screws [1] and then remove the fixing cover R [2]. Note: • Be careful not to touch the glass section of [2] the fixing heater lamp with bare hands. This may shorten the effective life of the heater • Be careful not to damage the surface of the lamp. [1] III DIS./ASSEMBLY fixing heater lamp. Especially when removing or reinstalling it, care should be taken not to contact and damage the inner surface of the fixing roller.
• When the installation is completed, check to see if the fixing heater lamp is set securely to the fixing plate and the faston terminal is properly installed. 3. Remove the connector [1] and take out the web motor wiring harness [3] from the clamps [2] at the 3 places. [3] [2] [1] 3-79