sinee — A90 User Manual

User Manual of A90 Series Inverter Function i output Valid Invalid Level output Valid Invalid Single pulse output Pulse output Valid Invalid width Fig. 7-13 Schematic Diagram of Level and Single Pulse Output of Digital Output Terminal level and single pulse, as shown in Fig. 7-13. For the level output, the output status of the The digital output terminal Y1 and relay output terminal R1 have two output types: function terminal is consistent with the function status; and for the single pulse output, the active level of a certain pulse width will not be outputted until the function is enabled. This function code is subject to bit operation.

For specific settings, refer to the description of the function code F03.06. 155 1: single pulse Function Default Function code name Parameter description Unit Attribute code setting F03.06 Positive/negative logic of digital output D7 D6 D5 D4 D3 D2 D1 D0 00000 ○ * * * * * R1 * Y1 0: positive logic is valid in the closed state/invalid in the open state 1: negative logic is valid in the closed state/invalid in the open state