sinee — A90 User Manual

User Manual of A90 Series Inverter to F14.34 correspond to F01.00 to F01.34, which are motor nameplate parameters, motor parameters and encoder parameters; the function code F14.35 corresponds to F00.01, which is used to select the motor drive mode; the function codes F14.36 to F14.76 correspond to F06.00 to F06.40, which are vector control parameters; and the function code F14.77 is used to select the acceleration/deceleration time of the motor 2. Only the parameters of F14.72 are described below. For the rest of the parameters, refer to the relevant parameters of the motor 1. F14.77=0 : the acceleration/deceleration time of the motor 2 is the same as that of the motor 1.

For details, see the description of the function codes F15.03 to F15.09; acceleration/deceleration time 1/2/3/4, corresponding to the function codes F00.14, F14.77=1/2/3/4 : the acceleration/deceleration time of the motor 2 is fixed as the F00.15/F15.03, F15.04/F15.05, F15.06/F15.07 and F15.08, respectively. 7.16 Auxiliary Function Parameter Group of F15 Group 229 Function Default Function code name Parameter description Unit Attribute code setting F14.77 Acceleration/decelerati on time options of motor 2 0: the same as motor 1 1: acceleration and deceleration time 1 2: acceleration and deceleration time 2 3: acceleration and deceleration time 3 4:

acceleration and deceleration time 4 0 ○ Function Function code Default Parameter description Unit Attribute code name setting F15.00 Jog frequency 0.00 to maximum frequency F00.16 Hz 5.00 ● F15.01 Jog acceleration time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 5.00 ● F15.02 Jog deceleration time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) s 5.00 ●