User Manual of A90 Series Inverter 67 frequency sources F00.13 Analog adjustment of synthetic frequency 0: synthetic frequency of main and auxiliary channels 1: AI1 * synthetic frequency of main and auxiliary channels 2: AI2 * synthetic frequency of main and auxiliary channels 0 ○ F00.14 Acceleration time 1 0.00~650.00 (F15.13=0) 0.0~6,500.0 (F15.13=1) 0~65,000 (F15.13=2) s 15.00 ● F00.15 Deceleration time 1 0.00~650.00 (F15.13=0) 0.0~6,500.0 (F15.13=1) 0~65,000 (F15.13=2) s 15.00 ● F00.16 Maximum frequency 1.00~600.00 Hz 50.00 ○ F00.17 Options of upper frequency limit control 0: set by F00.18 1: AI1 2: AI2 3: retention 4: VP (keyboard potentiometer) 5: retention 6:
percent setting of upper limit frequency communication 7: direct setting of upper limit frequency communication 0 ○ F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● F00.20 Running direction 0: consistent direction 1: opposite direction 0 ● F00.21 Reverse control 0: Allow forward/reverse running 1:
Prohibit reversing 0 ○ F00.22 Duration of forward and reverse dead zone 0.00~650.00 s 0.00 ● F00.23 Carrier frequency 1.0~16.0 (A90-4T1R5~A90-4T9R4B) 1.0~10.0 (A90-4T013B~A90-4T017B) 1.0~8.0 (A90-4T025B~A90-4T110B) 1.0~6.0 (A90-4T150~A90-4T304) kHz Model Confirm ● F00.24 Automatic adjustment of carrier frequency 0: Invalid 1: valid 1 1 ○