omron — BlobIntrinsicBoundingBoxRotation

BlobIntrinsicBoundingBoxRotation BlobIntrinsicBoundingBoxRotation VRESULT 1640 Rotation of the intrinsic bounding box with respect to the X-axis of the selected coordinate system. This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 1640, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1640, index_id, frame_id) Type Double Range Minimum: -180 Maximum: 180 Parameters ACE Reference Guide, 18317-000 Rev A Page 135 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.

tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the blob for which you want the result. ID 1640: the value used to reference this property. index id _ N/A frame id _ Frame containing the blob for which you want the result.