omron — ElapsedTime

ElapsedTime ElapsedTime VRESULT 1001 Total time elapsed (in milliseconds) during the last execution of the Locator tool. This time includes the time for the learn process, the time for the search process, and the overhead required to create and output the results structures. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1001, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1001, index_id, frame_id) Remarks This property returns the total elapsed time; it is not the used CPU time. Type Double Range Minimum: 0.0 Maximum:

unlimited Parameters ACE Reference Guide, 18317-000 Rev A Page 222 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ N/A ID 1001: the value used to reference this property. index id _ N/A frame id _ Index of the frame that contains the specified instance.