FitQuality FitQuality VRESULT 1803 Normalized average error between the calculated arc or line entity and the actual edges matched to the found entity. Fit quality ranges from 0 to 1, with 1 being the best quality. A value of 1 means that the average error is 0. Conversely, a value of 0 means that the average matched error is equal to Conformity Tolerance. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1803, index_id, frame_id ) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1803, index_id, frame_id ) Type Double Range Minimum: 0.0 Maximum:
1.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 246 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1803: the value used to reference this property. index id _ N/A frame id _ Index of the frame that contains the specified instance. Range: [1, ResultCount -1] $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.