omron — InstanceFitQuality

InstanceFitQuality InstanceFitQuality VRESULT 1317 Normalized average error between the matched model contours of the selected object instance and the actual contours detected in the input image. Fit quality ranges from 0 to 1, with 1 being the best quality. A value of 1 means that the average error is 0. Conversely, a value of 0 means that the average matched error is equal to ConformityTolerance. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1317, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1317, index_id, frame_id) Remarks In MicroV+/V+, the frame_id parameter is required. Type Double Range Minimum:

0.0 Maximum: 1.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 303 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1317: the value used to reference this property. index id _ N/A