InstanceFitQuality InstanceFitQuality VRESULT 1317 Normalized average error between the matched model contours of the selected object instance and the actual contours detected in the input image. Fit quality ranges from 0 to 1, with 1 being the best quality. A value of 1 means that the average error is 0. Conversely, a value of 0 means that the average matched error is equal to ConformityTolerance. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1317, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1317, index_id, frame_id) Remarks In MicroV+/V+, the frame_id parameter is required. Type Double Range Minimum:
0.0 Maximum: 1.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 303 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1317: the value used to reference this property. index id _ N/A