omron — PairPositionY

PairPositionY PairPositionY VRESULT 1922 Y-coordinate of the center of the selected pair. The position of a pair is defined as the middle of the line segment drawn from the X/Y-coordinates of the first and second edges of the pair. This property is read- only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 1922, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1922, index_id, frame_id) Type Double Range Boundaries of the input image. Parameters ACE Reference Guide, 18317-000 Rev A Page 427 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.

sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the pair for which you want the result. ID 1922: the value used to reference this property. index id _ N/A frame id _ N/A