V+ ACE Sight Module Documentation visionrot Countains the part Rotation in the vision coordinates reference frame reset_seq($myip, seq_id) Abstract Reset an ACE Sight sequence. Input Parameters Parameter Description $myip String containing the IP Address of the ACE Sight vision server seq_id Index of the sequence to reset Output Parameters None set_as_exec_mod($myip, seq_id, mode) Abstract Set the ACE Sight execution mode for a given sequence. Input Parameters Parameter Description $myip String containing the IP Address of the ACE Sight vision server seq_id Index of the sequence to reset mode Desired ACE Sight execution. 0 = Single execution mode; otherwise:
Continuous execution mode Output Parameters None ACE Reference Guide, 18317-000 Rev A Page 748