V+ Remote Library Documentation V+ Remote Library Documentation The V+ remote library allows a V+ application to access functionality on the PC. These programs are a sub- set of the Ace Server program module. Remote Library Error Codes If a problem is encountered when executing a remote library method, the following error codes can be returned: Error Code Description -1000 Unable to find the AceObject referenced in the remote command -1001 A general error has occurred while processing the remote command. See the AceServer event log for specific details.
-1002 The method referenced in a remote library execute command could not be found -1003 A general error has occurred while processing a remote execute invocation or property access. See the AceServer event log for specific details. - 10000 Server has stopped executing and the connection to the remote PC has been lost - 10001 The request has timed out - 10002 The referenced object does not exist - 10003 The field referenced in the remote object does not exist - 10004 The type of the referenced field is not compatible with the requested operation rm.app.event(value, wait.time, status) Abstract Generates an application event on the PC associated with this controller.
Input Parameters Parameter Description value Numeric code representing the event. wait.time The amount of time to wait for the operation to complete. ACE Reference Guide, 18317-000 Rev A Page 814