Delta Electronics AH — 7.9.3.1 Creating a CAM Chart in ISPSoft

AH Motion Controller – Operation Manual 2. Click (Setting) to open the setting window for the current E-CAM chart.  Master position: defines the display range of the master axis in the E-CAM curve area.  Slave position: defines the display range of the slave axis in the E-CAM curve area.  Resolution: defines the resolution of this E-CAM chart (max.: 2047) 3. You can click ( Insert a row) or (delete a row) to edit the Data setting area. Modifying the master/slave position in the table ill change the E-CAM curve in the E-CAM curve area immediately. _7 7-36