Wiring ASDA-B3 3 If you choose other brands of terminals, refer to the terminal block width and screw specifications in the following table: Note: 1. Select the correct O-type terminal or Y-type terminal corresponding to the servo drive and make sure the wire conforms to the specifications. 2. Use a crimping tool to properly crimp the terminal and wire. 3. Do not use bare wires for wiring, or the loose wires may cause accidents. 4. Use 600 V AC PVC wire for the power cable with the wiring length of 20 meters (65.62 feet) or less. 5. In the servo drive model column, 1 represents the product series and 2 represents the model code. 3-28 Wire diameter K. S. Terminals Inc.
Kise Terminal Kss Terminal Servo drive model R, S, T Y type O type Y type O type Y type O type 22 AWG SVBL1-3.7 RVBM1-3.7 SV 1.25-3 RV 1.25-3 YF1.25-3 20 AWG 16 AWG 14 AWG SVBL2-3.7 RVBM2-3.2 SV 3.5-3 RV 2-3 YF3.5-3S 12 AWG - - - 12 AWG SVBS5-4 RVBS5-4 SVS 5.5-4 RVS 5.5-4 YF5.5-4 10 AWG Servo drive model Width Screw ASD-B3 1 -0121- 2 7 mm M3 ASD-B3 1 -0221- 2 ASD-B3 1 -0421- 2 ASD-B3 1 -0721- 2 ASD-B3 1 -1021- 2 ASD-B3 1 -1521- 2 ASD-B3 1 -2023- 2 9.5 mm M4 ASD-B3 1 -3023- 2