3 i5601E Digital Display Factory Settings Sync Displayed only if a CAN Bus Control head is present. Displayed only if number of engines is two or more. Specifies how the synchronizer between engines should operate. EIM stands for Engine Interface Module, which if selected, requires the EIM to handle the Sync function. Pwr train sync: = Power Train Sync: The “slave” engine follows the “lead” engine in every shift or throttle position Cruise sync: The “slave” engine follows the “lead” engine only when the shift positions are same for both engines, and throttle levers are close to each other (within +/-5%). Lead Engine Displayed only if a CAN Bus Control head is present AND . . .
Number of Engines is two or more. Engine Sync selection is set to “Pwr Train.” Specifies which engine will lead (source) the engine speed. T (Troll Throttle) Engage Delay “T Engage Delay” indicates the rpm under which the troll is engaged. If the “T rpm Engage” value is set below the idle rpm, the trolling will never be engaged. If the value is set just above the idle rpm, On/ Off hunting of the troll function could occur. The value must be set at 800 or 1000 rpms. Displayed only if a CAN Bus Control head is present AND . . . Displayed only if Trolling Mode set for “SPLIT.” The value indicates the delay to be used when transitioning between the trolling range and the throttle range.
© 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 3:43 Menu Item Display Choices Function Sync NONE No Sync Pwr Train Power Train Sync Cruise Cruise Sync Menu Item Display Choices Function Lead Engine PORT Port Engine Lead STBD Starboard Engine will Lead Menu Item Display Choice Function T Engage Dly 0 0.0 seconds to 20 2.0 Seconds