10 Fieldwork settings 10.2 Feeder unit 67086 73190 10.2.4 Adjusting the front attachment drop rate (DOMINATOR 150) The drop rate of the front attachment can be adjusted by turning the knurled screw (1) on the flow control valve (2). 1 The drop rate should be adjusted when the hydraulic oil is at working temperature. The drop rate is adjusted on the knurled screw (1) and should be set so that the front attachment drops from the top to the bottom in about 5 to 6 seconds. 2 25066 6 2 7 25065 176 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 Drop rate Faster turn in the knurled screw Slower turn out the knurled screw