John Deere 450DLC — Pilot Shutoff Circuit Theory of Operation

TM2361 (24JUN08) 9015-15-42 450DLC Excavator Operation and Tests 062608 PN=486 Sub-System Diagnostics —Terminal B19 of monitor controller (A4) is connected contacts of both pilot shutoff switches. When the key to cab harness ground 4 (W38), through pilot shutoff switch is turned to the START position and ground is diode (V8) (terminals 1 and 2) and the normally open present at the coil of the starter relay, the starter relay contacts of both pilot shutoff switches. When ground is energizes and prevents the start circuit from operating. present at terminal B19, the monitor controller knows For more information, see Starting and Charging that the pilot shutoff circuit is functioning properly.

If Circuit Theory of Operation. (Group 9015-15.) ground is not present at terminal B19, the pilot control shutoff lever alarm indicator will appear on the monitor Monitor Security—When a warning alarm occurs display, alerting the operator that the pilot shutoff caused by a diagnostic trouble code (DTC) or when circuit is malfunctioning. For information on monitor the monitor security is active, terminal A4 of the alarms, see Alarm Occurrence Screen. (Operator’s monitor controller provides a path to ground for the coil Manual.) of starter relay (K4), through security diode (V4) (terminals 1 and 2) and engine stop switch (S14) NOTE:

The monitor controller must detect a ground at (terminals 5 and 6). A path to ground is also provided terminal B19 at all times, regardless of position to the coil of security relay (K5), through security diode of pilot shutoff lever. (V4) (terminals 2 and 3). —Terminal B12 of monitor controller is connected to When ground is available to the coil of the starter cab harness ground 4 (W38), through starter relay relay, the starter relay energizes when the key switch diode (V5) (terminals 2 and 3) and the normally open is turned to the START position. The energized relay contacts of both pilot shutoff switches.

Terminals B2 prevents the start circuit from operating when the 9015 15 42 and B12 are connected inside the monitor controller, monitor security system is active. For more so when ground is present at terminal B12, ground is information, see Starting and Charging Circuit Theory also available at the coil of pilot shutoff solenoid relay of Operation. (Group 9015-15.) (K2), causing the relay to energize. With pilot shutoff solenoid relay energized, and as long as security relay NOTE: For information on activation of monitor (K5) is de-energized, the path to ground is complete to security, see Incorrect Password Entered. pilot shutoff solenoid (Y10).

Solenoid is energized; pilot (Operator’s Manual.) hydraulics are enabled. When ground is available to the coil of the security —Terminal C31 of main controller (MCF) (A3) is relay, the security relay energizes, interrupting the connected to cab harness ground 4 (W38) through the ground path to the pilot shutoff solenoid. This causes normally open contacts of both pilot shutoff switches. the pilot shutoff solenoid to de-energize and prevents With ground available at terminal C31, the MCF knows the pilot hydraulics from being enabled (unlocked) the pilot shutoff is enabled. This input is used by the even if the pilot shutoff lever is in the forward optional fan reversing circuit.

For more information, (unlocked) position. see Main Controller (MCF) Theory of Operation. (Group 9015-15.) NOTE: The monitor controller provides a ground at terminal A4 for two seconds after the key —Terminal 2 (coil) of starter relay (K4) is connected to switch is turned to the ON position. The cab harness ground 4 (W38), through engine stop temporary ground at terminal A4 prevents switch (S14) (terminals 5 and 6), starter relay diode cranking of the engine until the monitor (V5) (terminals 1 and 2), and the normally open controller has time to fully power up. LD30992,0000216 –19–27APR06–3/3