John Deere 450DLC — Pump Learning Procedure

TM2361 (24JUN08) 9015-20-63 450DLC Excavator Operation and Tests 062608 PN=553 References Pump Learning Procedure The pump learning procedure uses inputs from the pump control pressure sensors while monitoring the output to the pump control solenoids to determine the pump swash plate position. IMPORTANT: Pump learning procedure must be performed if the hydraulic pump, hydraulic pump regulator, hydraulic pump control solenoid or main controller (MCF) are replaced. IMPORTANT: If pump learning procedure fails, new data is not stored. Main controller (MCF) will use previous pump learning data. Machine must meet the following criteria to perform pump learning procedure:

• No diagnostic trouble codes • Engine speed dial: fast idle • Auto-idle switch: Off • Power mode switch: HP • Pressure sensor: Zero output (pilot control lever in neutral) • Hydraulic oil temperature: 45—55°C (81—163°F) • Pilot shutoff lever: LOCK position • Learning switch: OFF 1. Connect to machine with Dr. ZX. See Personal Digital Assistant (PDA) Connection To Excavator Using Dr. ZX. (Group 9015-20.) 2. Under Main Controller: Monitor Display, select: • Pump Regulator Learning SW • Pump 1 Regulator Learning Condition • Pump 2 Regulator Learning Condition • Pump 1&2 Regulator Learning Status Select Start to view selected items.

Continued on next page LD30992,00004C8 –19–08JUN06–1/4 9015 20 63