TM2361 (24JUN08) 9025-05-38 450DLC Excavator Operation and Tests 062608 PN=676 Theory of Operation Fan Drive Pump Regulator Operation 201 209 200 204 208 31 221 222 202 203 212 214 213 216 33 –UN–25APR06 210 TX1006721 34 30 TX1006721 Fan Drive Pump Regulator Linkage Components 30—Servo Piston 201—Pin 209—Pin 214—Hole 31—Feedback Link 202—Pin 210—Pin 216—Pin 33—Load Spool 203—Pin 212—Lever 221—Decrease Flow Rate 34—Pilot Piston 204—Hole 213—Pin 222—Increase Flow Rate 200—Lever 208—Compensating Rod 9025 05 38 Fan Drive Pump Regulator Operation—The fan drive Fan Drive System Diagram and Operation.
(Group pump regulator is located at the top of the fan drive 9025-05.) pump, and is responsible for the control of the pump delivery flow rate. The pump control solenoid valve Supply oil from the fan drive pump is routed to the regulates the pilot control pressure according to small chamber of the servo piston (30), compensating signals received from the main controller (MCF). As piston (35), and the load spool (33). pilot control pressure increases, the pump delivery flow rate decreases.
For more information on the MCF and The pilot piston (34) moves against the spring (215) in the fan drive system, see Main Controller (MCF) response to pilot oil pressure from the pump control Circuit Theory of Operation (Group 9015-15) and see solenoid valve. Continued on next page OUT3035,000001D –19–27APR06–1/9