TM2361 (24JUN08) 9025-05-82 450DLC Excavator Operation and Tests 062608 PN=720 Theory of Operation During Normal Operation—The bucket regenerative 170 check valve (172) is closed and the regenerative operation stops. As pressure increases in the bottom side of the bucket cylinder (170), the piston of the bucket 172 regenerative switch valve (91) pushes a plunger. As speed of the bucket cylinder increases, the amount of return oil (184) flow is determined from the top side of the bucket cylinder to the hydraulic oil tank (47).
93 15—From Pump 1 47—Hydraulic Oil Tank 91—Bucket Regenerative Switch Valve 94 93—Power Passage Check Valve (bucket lift check) 94—Bucket Spool 170—Bucket Cylinder 91 –19–19APR06 172—Bucket Regenerative Valve 180—Supply Oil 47 PRESSURE OIL 15 182—Pilot Oil FROM PUMP 1 184—Return or Pressure-Free Oil 185—Regenerative Return Oil 180 182 185 TX1006657 TX1006657 9025 05 170 91 47 94 –UN–20APR06 172 180 182 TX1006682 184 TX1006682 During Normal Operation LD30992,0000261 –19–26APR06–2/2 82