TM2361 (24JUN08) 9025-05-107 450DLC Excavator Operation and Tests 062608 PN=745 Theory of Operation Travel Motor Speed Circuit Operation 5 3 6 4 2 1 1 7 2 –UN–25APR06 9 8 10 TX1006978 11 TX1006978 Travel Motor Slow Speed Operation 1—Swashplate Piston 4—Spool 6—Spool 9—Supply Oil 2—Swashplate 5—From Travel Speed 7—Counterbalance Valve 10—Return Oil 3—Travel Speed Selector Solenoid Valve (SB) 8—Cylinder Block Valve Travel Motor Slow Speed Operation—When slow selector valve (3) spools (4 and 6).
Springs hold the speed travel (turtle) mode is selected, the pump and spools in slow speed travel (turtle) position, and the oil valve controller sends a control signal to the power acting on the swashplate pistons (1) is routed to return boost solenoid to increase system relief pressure through the center of the travel speed selector valve setting but does not send a control signal to the travel spools. The swashplate (2) is fixed at maximum speed solenoid valve (SB). displacement. At maximum displacement the motor turns at slow speed with high torque.
When the travel speed change solenoid is de-energized pilot oil is not routed to the travel speed Continued on next page LD30992,000026A –19–25APR06–1/2 9025 05 ,107