Boom Raise Power Is Low During Digging Diagnostic Procedure NOTE: If function operating speeds are very slow also, perform All Hydraulic Functions Slow Diagnostic Procedure first. (Group 9025-15.) –1/1 TM2361 (24JUN08) 9025-15-17 450DLC Excavator Operation and Tests 062608 PN=767 Diagnostic Information 1 Pump 1 or Pump 2 Delivery Pressure Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and take boom raise over relief. Record pressure. Is pump 1 or 2 delivery pressure below 30.4 MPa? YES: Adjust main relief valve.
See Main Relief and Power Digging Valve Test and Adjustment. (Group 9025-25.) NO: Main relief valve pressure is ok. Diagnostic procedure complete. – – –1/1 1 DTC Check See Reading Diagnostic Trouble Codes With Monitor Display. (Group 9015-20.) See Reading Diagnostic Trouble Codes With Service ADVISORDiagnostic Application Are any of the following DTC displayed? • 11302.03 See Boom Raise Pilot Pressure Sensor Voltage High. (Group 9001-10.) • 11302.04 See Boom Raise Pilot Pressure Sensor Voltage Low. (Group 9001-10.) • 11404.03 See Power Dig Solenoid (SG) Valve Feedback Current High. (Group 9001-10.) • 11404.04 See Power Dig Solenoid (SG) Valve Feedback Current Low. (Group 9001-10.) YES:
Diagnose and repair as required to clear displayed DTC. Diagnostic procedure complete. NO: Go to Power Digging Switch Check. – – –1/1 9025 15 17 2 Power Digging Switch Check Key on, use monitor service menu to display Power Digging Switch. See Monitor Service Menu Operation. (Group 9015-16.) Push power dig switch on control lever and observe monitor. Does power digging switch indicator change from off to on? YES: Go to Power Boost Pressure Check. NO: Replace power digging switch or wiring. – – –1/1