John Deere 450DLC — Both Tracks Do Not Rotate Or Move Slowly In Either Direction Diagnostic Procedure

Both Tracks Do Not Rotate Or Move Slowly In Either Direction Diagnostic Procedure IMPORTANT: If dig and swing function normally, the pilot pump is considered to be ok. If all functions are slow, perform All Hydraulic Functions Slow Diagnostic Procedure first. (Group 9025-15.) –1/1 TM2361 (24JUN08) 9025-15-41 450DLC Excavator Operation and Tests 062608 PN=791 Diagnostic Information 3 Right Travel Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Switch pump 1 delivery sensor with pump 2 delivery sensor. Is does right track now move? YES: Replace pump 1 delivery sensor. NO: Flow check pump 1. Perform Pump Flow Test.

(Group 9025-25.) – – –1/1 4 Pump 1 Control Pressure Check Key on, use monitor service menu to display Pump 1 Control Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Jack up right track so track is free to rotate without ground resistance. Monitor pump 1 control pressure on monitor while fully engaging right track control lever. Does the control pressure change when travel control lever is moved? YES: Go to Pump 1 Pressure Sensor Swap Check. NO: Replace pump 1 pressure regulator. – – –1/1 5 Pump 1 Pressure Sensor Swap Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend.

(Group 9015-10.) Switch pump 1 regulator sensor with pump 2 regulator sensor. Fully engaging right track control lever. Is does right track now move? YES: Replace regulator pressure sensor. NO: Go to Pump 1 Control Solenoid Valve Check. – – –1/1 9025 15 41 6 Pump 1 Control Solenoid Valve Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Inspect pump 1 control solenoid for sticking. Is control solenoid in good working condition? YES: Diagnostic procedure complete. NO: Replace pump 1 control solenoid valve. – – –1/1