Komatsu — 20-201--.pdf

20 TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ENGINE.......... 20- 2 STANDARD VALUE TABLE FOR CHASSIS........ 20- 3 TESTING AND ADJUSTING................................ 20-101 TROUBLESHOOTING ......................................... 20-201 Note the following when making judgements using the standard value tables for testing, adjusting, or trou- bleshooting. 1. The standard value for a new machine given in the table is the value used when shipping the machine from the factory and is given for reference. It is used as a guideline for judging the progress of wear after the machine has been operated, and as a reference value when carrying out repairs. 2.

The service limit value given in the tables is the estimated value for the shipped machine based on the results of various tests. It is used for reference together with the state of repair and the history of operation to judge if there is a failure. 3. These standard values are not the standards used in dealing with claims. When carrying out testing, adjusting, or troubleshooting, park the machine on level ground, inset the safety pins, and use blocks to prevent the machine from moving. When carrying out work together with other workers, always use signals and do not let unauthorized people near the machine. When checking the water level, always wait for the water to cool down.

If the radiator cap is removed when the water is still hot, the water will spurt out and cause burns. Be careful not to get caught in the fan, fan belt or other rotating parts. PC130-7 20-1 (1)