— MIL-STD-3001-4(AS) — Digital Technical Information, Part 4 of 8 (2001)

Downloaded from https://www.everyspec.com MIL-STD-3001-4(AS) not on the artwork. Index numbers will be used only to identify items that do not have reference designations. 5.3.11.1.8.8 Polarity identification. When applicable, the polarity of electronic components shall be identified on the component of all maintenance illustrations. 5.3.11.1.8.9 Reference designations. Illustrations that depict electrical components should include reference designation after the index number. If an orthographic view is prepared, the reference designation may be placed within the view of the part, if space permits. 5.3.11.2 Separate IPB work packages ipbwp > ( for paged-based manuals only ).

When specified by the requiring activity, a separate IPB work package or a series of IPB work packages shall be prepared. When more than one IPB work package is required, the IPB work packages may be presented immediately following each applicable maintenance WP, or all IPB work packages shall follow the last maintenance WP in the manual. An introduction for the IPB shall be included in the introduction to the manual. 5.3.11.2.1 IPB work package content. Each IPB work package shall consist of an illustration or a series of illustrations and the related Group Assembly Parts List (GAPL).

When usable on codes are used in the GAPL, a list of the usable on codes and an explanation of each code shall be provided at the end of the GAPL. The technical content requirements for the GAPL are identical to those provided in 5.3.11.1 b through 5.3.11.1.8.9. 5.3.12 Wiring/cabling diagram work packages wirediawp >. Wiring diagrams or cabling diagrams required to support the maintenance procedures may be included in separate work packages, especially when a large number of wiring or cabling diagrams are required.

Wiring/cabling diagrams shall be developed that adequately contain the maintenance data required by the technician to complete the maintenance task for aircraft system, aircraft wiring or equipment maintenance. A series of wiring diagram WPs shall be developed, as required, to illustrate the wiring of all aircraft systems, subsystems, and equipment. When aircraft weapons systems provide separate wiring diagram manuals, a reference or link shall be made in lieu of creating a separate WP. Wiring diagram WPs may have an introduction intro >. 5.3.13 Wire run lists work packages wirelistwp >.

Wire run lists required to support the maintenance procedures may be included in separate work packages, especially when these wire run lists are large in size. Wire run list work packages shall contain tables listing all wires for the aircraft systems, subsystems, and equipment. Wire list WPs may have an introduction intro >. Wires shall be listed in alphanumeric sequence by system wire number or reference designation. At a minimum, the following data shall be provided for each wire listed. a. The wire from-to destination by item reference designation/pin number. b. Wire size. c. Wire number identification and part number, if applicable. d. Any pertinent remarks, if applicable. 6. NOTES .

The notes in section 6 of MIL-STD-3001-1 apply this Part. 29