Delta DVP — 6.2.2 Input Point Wiring

Chapter 6 Wiring, Communication Setting and Network Construction 6.2.2 Input Point Wiring There are two types of DC inputs, SINK and SOURCE. See the details for the wiring in the following two modes.  Sink Mode Under Sink mode, the simplified model is shown below and the current flows into the common ports S0 and S1. Motion Controller Motion Controller Sinking S0 Sinking S1 24VDC 24VDC 00 10 Figure 6.2.2.1 See the relevant wiring circuit in the following figures.  The input points of the motion controller, 00~07 correspond to S0 as shown below.

Motion Controller 24VDC S0 Common ) ( Switch 00 Input ( ) 6_ Figure 6.2.2.2  The input points of the motion controller, 10~17 correspond to S1 as shown below. Mot ion Controller 24VDC S1 Common ( ) Switch 10 Input ( ) Figure 6.2.2.3 6-7