Delta · DVP · 2 pp.
DVP DU
Related manuals
Document text
Indication of the connected MPU model Indication of internal data storage model Password key setting of TC-01 can be set via WPLSoft. The purpose is to read/write to the key-locked PLC as long as the password setting is identical to the one in the PLC. To unlock the password key setting, please use WPLSoft as well. b) TC-01 has password key setting, therefore, only if the PLC has no password protection or with the same password with TC-01 can the writing proceeds. It also writes the password to the PLC for c) Password key clear (KEY CLR): Same with the above operation. Open WPLSoft, select [TC-01 3. Clear P, D, F of TC-01:
select the device (P, D or F) to be cleared, press + simultaneously, then press ESC. P(Program) D (Data Register) F (File Register) Reading F (file register) You can press ESC to pause reading. d1EC is the CHKSUM of writing program 2746 is the CHKSUM of writing data Finish reading Finish reading TC-01 „ In RD or WR mode, press ESC button and hold for 3 seconds or more to enter password setting. See the right figure: 5 TC-01 OPERATION 1. Switch the DU-01 to TC-01 mode (please see the back of the DU-01), and select RD (to read P, D and F in the MPU of PLC) or WR (to write the data in P, D, F of DU-01 to the MPU of PLC). „ Open WPLSoft Ц [Setting] Ц [TC-01 password key setting].
Select [Enter TC-01 password key], and operate as instructed. „ After setting, the display is shown as right figure. (KEY SET), then press ESC to exit. Setting reading range. (default start & end addresses are latched area range. User can re-set it.) RD read mode P,D,F selection Enter start address Enter end address Reading processing... You can press ESC to pause reading. Finish reading Note: P: Program, D: Data register, F: File register password key clear], and operate as instructed. Confirm Device + 2. TC-01 Password Key Setting a) Password Key Setting added protection. 4. RD mode description: Reading P (Program). You can press ESC to pause reading. Finish reading. 2.
Connecting to DVP series PLC via accessory cable (No need to shut down the MPU) Enter a number Number Selection Specified No. Display Enter Set Value Press to complete entering & return *Note: not include system operation mode setting Monitor status of 8 consecutive devices from the specified number Press and hold for 3 sec. Until shows + Sleep mode activated if no button is pressed within 30 seconds Specify a number Force On/Off setting 4. Please see the back page for detail information about the process of each mode. OK ESC ESC Monitor Mode Press + 3 INSTALLATION & WIRING 1.
Direct mounting to the expansion slot in the MPU of the EP/EH series OK OK + buttons simultaneously) Please shut down the MPU of the PLC while installing the DU-01. The DU-01 is connected via a high-density connector. Therefore, please see the above figures for proper operation. Put the face-up DU-01 slantly in the expansion slot, than push it down in arrow direction. DO NOT push it down vertically, so 4 TS-01 OPERATION 1. Switch DU-01 to TS-01 mode. (Please see the back of the DU-01) Press and hold for 3 sec. Time & device content Operation Mode ESC OK Press and hold for 3 sec. Press and hold for 3 sec. Press and hold for 3 sec.
Confirm & update time Number Selection OK Device confirm Device confirm Any mode* Sleep mode DVPDU-01 Digital Setup Display Instruction Sheet Auto Save No Save OK OK Time Mode ESC ESC OK Display Selection ESC as to avoid damage. YY-MM-DD HH-MM-SS Device Selection Device Selection X, Y, M, S T, C, D CR 2. Main Process ESC 1. In TS-01 mode, DU-01 (specified as TS-01 hereof) has the following functions: • Read/Write of both internal devices of PLC (eg. perpetual calendar, bit devices (X, Y, M, S) and word devices (T, C, D)) and the Control Register (CR) inside of the expansion units. • Supports the read/write of 32-bit data register. • Sets Start-up display and power save mode.
• Monitors the devices. • If connected with accessory cable to ES-series without perpetual calendar, the Time Display will start from 00-00-00 calculated by the microprocessor of DU-01 (timing error may occur). • Gives RUN-STOP command to the PLC. 2 W: write (WR) indication (TC-01) 13 Word devices T, C, D, DD (32-bit) indication 14 Bit devices X, Y, M, S indication 2. In TC-01 mode, DU-01 (specified as TC-01 hereof) has the following functions for DVP all series: • Read/write the program P, data register D and file register F from PLC. • Copies program and data. • Supports the password protection of the PLC. 1 P: program area indication (TC-01) 3 R:
read (RD) indication (TC-01) 4 “In communication” indication 5 D: Data Register indication (TC-01) 7 CR: Control Register indication (Expansion Module) 8 ER: Error message indication 10 Enter button indication 11 K (Decimal), H (Hexadecimal) indication 15 Digit backspace / Run (TC-01) 17 Enter a number or select a device 19 Enter a number or select a device 6 F: File Register indication (TC-01) 12 Contacts & coils of timer / counter indications 16 Back to previous status Back of the DU-01 9 Display Area 18 Confirm 2 INTRODUCTION DU-01 Digital Setup Display has two operation modes, TS-01 and TC-01. The switch for mode selection is at the back of the DU-01. Factory setting is TS-01 mode.
The current operation 1 WARNING 4 3 2 1 5 6 7 8 9 „ Overview of the Product - Names of Parts ESC OK DU-01 Please shut down the MPU of the PLC while installing the DU-01. The DU-01 is connected via a high-density connector. Therefore, please see the figures on the right for proper operation, so as to avoid TC-01 mode shows at every time of power up. damage. TS-01 P(Program) F (File R Monitor Mode Press + + Any mode* Time & device Until shows content Sleep mode activated if no button is pres within 30 seconds Sleep mode
K „ Various process for operation modes under TS-01 mode K K K Writing to F (File Register) in PLC. You can press ESC to pause writing during TC-01->PLC. d1EC is the CHKSUM of writing data. The accessory cable is for connecting DU-01 (the expansion COM port in above fig.) and DVP-series PLC COM1 (RS-232) port. Therefore, the DU-01 can be connected to ES/SS/EX and SA/SX models via the cable as well as directing installed in the expansion slot of EP/EH models. Error-00 P-read error. PLC is password-locked while the TC01 is with wrong or no password key. Please unlock the password setting on PLC or set password in TC-01 via WPL. Error-01 P-write error.
PLC is password-locked while the TC01 is with wrong or no password key; or the source model differs from the destination model. Error-02 D-read error. Illegitimate read range (read range only available for the general data registers of each models, not including special D) P (Program) D (Data Register) F (File Register) Finish writing. Finish writing DVP-PLC COM1 Connecting to (RS-232 Port) Expansion COM Port Error-03 D-write error. The source model differs from the destination model. Error-05 F-write error. The source model differs from the destination model. Start End + 6 DIMENSIONS & ACCESSORY Code Code Explanation & Troubleshooting 7 ERROR CODE TABLE Setting reading range.
(default start & end addresses is latched area range. User can change it.) d1EC is the CHKSUM of writing data. Finish writing d1EC is the CHKSUM of writing data. Error-04 F-read error. ES series does not have file registers. WR writing mode P,D,F selection Device Confirm Finish writing Error-06 PLC is running. Writing to P is forbidden. + ESC OK DU-01 Blink alternatively 4. WR mode description: Writing to P (Program) in PLC. You can press ESC to pause writing during TC-01-> PLC. Finish writing. Finish writing 4. WR mode description: WR writing mode + P,D,F selection Device Confirm Various process for operation modes under TS-01 mode Sleep mode setting (On: activate, Off:
deactivate) Fill 0 setting (fill 0 before number or not) (On: not to display 0, Off: display 0) Start-up display setting(On: allow to customize start-up display, System operation Off:
Default time display) mode setting Auto Save setting R W P D F CR ER Time display mode K H X Y M S T C D DD ESC + OK Mode selection On/Off Select yy-mm-dd/hh-mm-ss PLC calendar setting R W P D F CR ER Confirm & update the time OK Time display mode K H X Y M S T C D DD ESC + OK Field selection Set the contents ESC for setting The right four digits show 8 consecutive displays/settings that starts from Y10 The left four digits show device's number W P D F CR ER W P D F CR ER Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 K Y10,Y12,Y15,Y17 are On Device select mode K (Depends on actual output of the PLC) W P D F CR ER K Press and hold for 3 sec.until the blinking cursor shows OK Device status display OK OK K Move the bit to Select device confirm device dM igo itv te t bo t h se Set device's number desired device's F seo tr tc ine gd On/Off o e e t number X, Y, M, S ESC ESC Use to switch between K (decimal) / H (hexadecimal) display mode.
W P D F CR ER For 32-bit registers, use to move to display the two left-most digits. At this time, indicator will light up. Device select mode DD stands for 32-bit data register K Both timer and counter have coils & contacts monitor. W P D F CR ER K Current value OK OK OK display K (Press and hold for 3 sec.) Move to the Word device Select device Confirm device digit to be set Set the number ESC T, C, D, DD ESC ESC For example: Display two left-most digits W P D F CR ER Ente tor S me ot nV ita olu r e m & o dr eeturn (Press and hold for 3 sec.) for 32-bit register.
Current value OK display OK Enter Set Value mode W P D F CR ER K Move to the digit K Enter Set Value ESC Device number setting to be set T, C, D, DD ESC CR number Expansion unit number (0,1,2...7) W P D F CR ER K (Press and hold for 3 sec.) Specify the expansion Current value OK Specify CR number OK OK Enter Set Value mode unit number display K select device confirm CR 32-bit 16-bit ESC ESC Device select mode R W P D F CR ER Device select mode K H X Y M S T C D DD ESC + OK PLC status display PLC status switch Time display mode P (Program) D (Data Register) F (File Register) Blink alternatively Writing to P (Program) Writing to F in PLC. Start + End (File Register) in PLC.
You can press ESC You can press ESC to pause writing during Setting reading range. to pause writing during TC-01-> PLC. (default start & end TC-01->PLC. addresses is latched area range. User can change it.) Finish writing. Finish writing. d1EC is the CHKSUM d1EC is the CHKSUM of writing data. Finish writing of writing data. d1EC is the CHKSUM of writing data. Finish writing Finish writing Finish writing 6 DIMENSIONS & ACCESSORY Connecting to DVP-PLC COM1 (RS-232 Port) ESC OK DU-01 Expansion COM Port The accessory cable is for connecting DU-01 (the expansion COM port in above fig.) and DVP-series PLC COM1 (RS-232) port.
Therefore, the DU-01 can be connected to ES/SS/EX and SA/SX models via the cable as well as directing installed in the expansion slot of EP/EH models. 7 ERROR CODE TABLE Code Code Explanation & Troubleshooting P-read error. P Error-00 key. Please unl LC is password-locked while the TC01 is with wrong or no password ock the password setting on PLC or set password in TC-01 via WPL. P-write error. P Error-01 key; or the sour D-read error. Ill Error-02 registers of eac LC is password-locked while the TC01 is with wrong or no password ce model differs from the destination model.
egitimate read range (read range only available for the general data h models, not including special D) Error-03 D-write error. T Error-04 F-read error. E Error-05 F-write error. T Error-06 PLC is running. he source model differs from the destination model. S series does not have file registers. he source model differs from the destination model. Writing to P is forbidden.