2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-59 ES SA Off STOP RUN EH2 EH3 Special D Function EX SX Attribute Latched Default SV SV2 SS SC On RUN STOP D1133* SA/SX: start No. of register D for Y0 special high-speed pulse output (50kHz) (Not available in SX V3.0 and above) SC V1.4 and versions above: start No.
of _ register D for Y10 2-axis synchronous control output ╳ ○ ╳ ╳ 0 - - R/W NO 0 Number of pulses in the deceleration area of the positioning instruction (Low word) ╳ ╳ ○ ○ 0 - - R NO 0 D1134* Number of sections in Y10 output for 2-axis synchronous control (available in SC V1.4 and _ versions above) ╳ ○ ╳ ╳ 0 - - R/W NO 0 Number of pulses in the deceleration area of the positioning instruction (High word) ╳ ╳ ○ ○ 0 - - R NO 0 D1135* SC V1.4 and versions above: start No.
of _ register D for Y11 2-axis synchronous control output ╳ ○ ╳ ╳ 0 - - R/W NO 0 Pulse number for masking Y2 (Low word) When M1158 = ON and the pulse number for masking Y2 is not 0, enabling Y2 in the instruction DDRVI/DPLSR and masking X6 interrupt.
╳ ╳ ╳ ○ 0 - - R/W NO 0 D1136* Number of sections in Y11 output for 2-axis synchronous control (available in SC V1.4 and _ versions above) ╳ ○ ╳ ╳ 0 - - R/W NO 0 Pulse number for masking Y2 (High word) When M1158 = ON and the pulse number for masking Y2 is not 0, enabling Y2 in the instruction DDRVI/DPLSR and masking X6 interrupt ╳ ╳ ╳ ○ 0 - - R/W NO 0 D1137* Address where incorrect use of operand occurs ○ ○ ○ ○ 0 0 - R NO 0 D1140* Number of right-side special extension modules (max. 8) ○ ○ ○ ○ 0 - - R NO 0 D1142* Number of points X in digital extension unit ○ ○ ○ ○ 0 - - R NO 0 D1143* Number of points Y in digital extension unit ○ ○ ○ ○ 0 - - R NO 0 D1144* SA: Start No.
of register D for Y0 adjustable acceleration/deceleration pulse output (Not available in SX V3.0 and above) EH2/SV: The instruction DRVI calculates in advance the value in the data register for Y0. ╳ ○ ╳ ╳ 0 - - R/W NO 0 D1145* Number of left-side special extension modules (max. 8) (only available in SV) ╳ ╳ ○ ╳ 0 - - R NO 0 D1147 Type of memory card b0 = 0: no card existing (H0000) b0 = 1: with memory card b8 = 0: memory card Off (HFFFF) b8 = 1: memory card On (H0101) ╳ ╳ ○ ○ 0 - - R NO 0 D1149 Type of function extension card 0: no card 1: RS-232 card (DVP-F232), Digital Setup Display (DVPDU-01) 2: RS-422 card (DVP-F422) 3: COM3 card (DVP-F232S/DVP-F485S) 4:
analog rotary switch card (DVP-F6VR) 5: digital switch card (DVP-F81D), Digital input extension card (DVP-F41P) 6: transistor output card (DVP-F2OT) 8: Analog input card (DVP-F2AD) 9: Analog input card (DVP-F2DA) 10: frequency measurement card (DVP-F2FR) 11: Ethernet communication function extension card (DVP-FEN01) 12: CANopen communication function extension card (DVP-FCOPM) 13: RS-485 card (DVP-F485) ╳ ╳ ○ ○ 0 - - R NO 0 D1150 Table count register in multi-group setting comparison mode of DHSZ command ╳ ╳ ○ ○ 0 0 0 R NO 0