Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Parameter functions: In position mode, enables/disables adjustment of electronic gear ratio multiplier via analog setting. P1-33=0 : Disable electronic gear ratio adjustment via analog. P1-33=1 : Adjust via analog input terminal AI1 P1-33=2 : Adjust via analog input terminal AI2 Parameter functions: Sets the multiplier for adjustment of electronic gear ratio via analog. When P1-33 is set as 1 or 2 and P1-02 = 0 (when setting electronic gear ratio in the numerator/denominator method), this parameter is used to set the multiplier corresponding to the analog.
If it’s set as 1.00, it means the multiplier corresponding to every 100 mV analog is 1.00. Analog voltage (mV) 100 Electronic gear ratio = Caution ☞ 1. The P1-04 in the formula can be switched to P1-08, 10 or 12 based on the status of DI terminal. 2. Please note that the analog involves hysteresis, dead zone, offset and etc. subject to settings of P6 functions.
140 P1-33 Analog adjustment options of electronic gear ratio Initial value 0 Communication address 0121H Unit - Time of taking effect With immediate effect Setting range 0~2 Data size 16bit Control mode P P1-34 Analog adjustment multiplier of electronic gear ratio Initial value 1.00 Communication address 0122H Unit - Time of taking effect With immediate effect Setting range 0.01~10.00 Data size 16bit Control mode P