Technical Manual for EA350 Analog Pulse Type Servo Driver V101 12.5.1 Common features of servo motors: 12.5.2 Holding brake specification: 1: The holding brake is used to keep the motor locked after stop, and cannot be used for braking. 2: A 24V power source shall be provided by the user for the holding brake, and it is prohibited to connect the holding brake to the 24V power in the servo driver. The 24V power source shall have a capacity that is at least 1.5 times the rated power of the holding brake (excluding capacity of any 24V power source for other devices). 3: The action time of the holding brake may differ for different circuits.
The time provided above is only for reference, and the actual time depends on the physical product. 4: Static friction torque refers to the static friction torque provided by the brake when the motor is static; if there is external impact, keeping the motor static cannot be assured.
258 Motor insulation level F Class Withstand voltage of insulation 1500V 60s Insulation resistance DC500V, above 10MΩ Thermal resistance level of the motor B Protection level Fully-closed self cooling type, IP65 (except for the shaft running-through part) Service environment Ambient temperature 0-40°, RH 20%~80% (without dew condensation) Installation method Flange installation Rotation direction Rotate counterclockwise (CCW) under a forward command if viewed from the load side Motor flange Rated torque of motor Rated Static friction Rated Closing Release Set the closing Set the release size voltage torque power voltage voltage action time action time mm Nm VDC Nm W VDC VDC ms ms 40 0.32≤ 24 0.35 3.5 22 1.5 63 55 60 0.64~1.27 2 6.3 80 1.3~3.5 4 10.4 87 72 86 3.2~3.5 4 10.4 110 2~6 10 11.6 130 3.2~15 20 19.5 110 95 180 17~35 44 25 140 120 180 ≥36 74 45 152 130 200 35~95.5 120 95 165 140 230 70~184 200 120 230 180