electrolux EWM10 — 599735408en

A.D.L. 10 / 2010 Description Possible fault Reset Faulty triac for drain pump ѓ Faulty wiring. ѓ Drain pump faulty. ѓ Main circuit board faulty. Malfunction in sensing circuit on triac for drain pump ѓ Main circuit board faulty. ѓ Drain pipe improperly positioned. ѓ Water pressure too low. ѓ Water fill solenoid valve faulty. ѓ Leaks/clogging of pressure switch water circuit. ѓ Pressure switch faulty. ѓ Drain tube kinked/clogged/improperly positioned. ѓ Drain filter clogged/dirty. ѓ Faulty wiring. ѓ Pressure switch faulty. ѓ Drain pump rotor blocked. ѓ Drain pump faulty. ѓ Main circuit board faulty. ѓ Tap closed. ѓ Water pressure too low. ѓ Drain pipe improperly positioned.

ѓ Water fill solenoid valve faulty. ѓ Leaks from pressure switch water circuit. ѓ Pressure switch faulty. ѓ Faulty wiring. ѓ Main circuit board faulty. Water fill difficulty during washing Drain difficulty during washing 6.3 Alarm Summary Table Water leaks ALARM CODE E11 E13 E21 E23 E24 ALARM CODE Description Possible fault Machine status/action Reset E11 Water fill difficulty during washing ƒ Tap closed. ƒ Water pressure too low. ƒ Drain pipe improperly positioned. ƒ Water fill solenoid valve faulty. ƒ Leaks from pressure switch water circuit. ƒ Pressure switch faulty. ƒ Faulty wiring. ƒ Main circuit board faulty.

Cycle is paused with door locked START/RESET E13 Water leaks ƒ Drain pipe improperly positioned. ƒ Water pressure too low. ƒ Water fill solenoid valve faulty. ƒ Leaks/clogging of pressure switch water circuit. ƒ Pressure switch faulty. Cycle is paused with door locked START/RESET E21 Drain difficulty during washing ƒ Drain tube kinked/clogged/improperly positioned. ƒ Drain filter clogged/dirty. ƒ Faulty wiring. ƒ Pressure switch faulty. ƒ Drain pump rotor blocked. ƒ Drain pump faulty. ƒ Main circuit board faulty. Cycle is paused (after 2 attempts) START ON/OFF RESET E23 Faulty triac for drain pump ƒ Faulty wiring. ƒ Drain pump faulty. ƒ Main circuit board faulty.

Safety drain cycle - Cycle stops with door open. RESET E24 Malfunction in sensing circuit on triac for drain pump ƒ Main circuit board faulty. Safety drain cycle - Cycle stops with door unlocked RESET