A.D.L. 10 / 2010 ѓ Faulty wiring. ѓ Motor faulty; ѓ Inverter board faulty; ѓ Motor-inverter wiring faulty. ѓ Inverter board faulty. ѓ Motor faulty. ѓ Motor-inverter wiring faulty. ѓ Inverter board faulty. ѓ Motor faulty; Input voltage is lower than 175V. ѓ Faulty wiring. ѓ Inverter board faulty; Input voltage is too high - beyond 430V. ѓ ѓ Inverter board faulty ѓ ѓ Inverter board faulty. ѓ Main board faulty. ѓ Faulty wiring. ѓ Inverter board faulty. ѓ Main board faulty. ѓ Line interference. ѓ Faulty wiring. ѓ Main board or Inverter board faulty. Description ѓ conditions. ѓ Inverter board faulty. ѓ NTC open (on the Inverter board) ѓ Abnormal motor operation (overload).
ѓ Motor-inverter wiring faulty. ѓ Motor faulty. ѓ Inverter board faulty. No signal from motor tachometric generator Overheating on heat dissipator for Inverter (>88°C) Communication error between Inverter and main PCB Inverter is drawing too much current (>15A) Inverter is drawing too much current (>4.5A) No signal from tachometric generator for 3 seconds Data transfer error between Inverter and main PCB Inverter PCB fails to start the motor ALARM CODE E52 E57 E58 E59 E5A E5H E5C E5D E5E E5F ALARM CODE Action Description Possible fault Reset Machine status E52 No signal from motor tachometric generator Faulty wiring.
Motor faulty; Inverter board faulty; Cycle blocked with door locked after 5 attempts. ON/OFF RESET E57 Inverter is drawing too much current (>15A) Motor-inverter wiring faulty. Inverter board faulty. Motor faulty. Cycle blocked with door locked after 5 attempts. ON/OFF RESET E58 Inverter is drawing too much current (>4.5A) Abnormal motor operation (overload). Motor-inverter wiring faulty. Motor faulty. Inverter board faulty. Cycle blocked with door locked after 5 attempts. ON/OFF RESET E59 No signal from tachometric generator for 3 seconds Motor-inverter wiring faulty. Inverter board faulty. Motor faulty; Cycle blocked with door locked after 5 attempts.
ON/OFF RESET E5A Overheating on heat dissipator for Inverter (>88°C) Overheating caused by continuous operation or ambient conditions. Inverter board faulty. NTC open (on the Inverter board) Cycle blocked with door locked after 5 attempts. ON/OFF RESET E5H Input voltage is lower than 175V. Faulty wiring. Inverter board faulty; Cycle blocked with door locked after 5 attempts. ON/OFF RESET E5C Input voltage is too high - beyond 430V. Input voltage is too high (measure the grid voltage). Inverter board faulty Cycle blocked with door locked after 5 attempts ON/OFF RESET E5D Data transfer error between Inverter and main PCB Line interference. Faulty wiring.
Main board or Inverter board faulty. ---------------- E5E Communication error between Inverter and main PCB Faulty wiring between main board and Inverter. Inverter board faulty. Main board faulty. Cycle blocked after 5 attempts. ON/OFF RESET E5F Inverter PCB fails to start the motor Faulty wiring. Inverter board faulty. Main board faulty. Cycle blocked with door open after 5 attempts. ON/OFF RESET