sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter Function i output Valid Invalid Level output Valid Invalid Valid delay Invalid delay Single pulse output Valid Invalid Pulse output width Fig. 7-15 Schematic Diagram of Level and Single Pulse Output of Digital Output Terminal When the status of the selected function changes, the corresponding output terminal will make a response with delay based on the function code settings. At present, the terminals Y1 and R1 support this function. Details under default conditions: When the function changes from the invalid to valid status and is maintained with the valid delay, the corresponding output terminal will output the active level.

When the function changes from the valid to invalid status and is maintained with the invalid delay, the corresponding output terminal will output the inactive level. ★ If the function code is set to 0.000s, the delay will be invalid. When one function output terminal is in the single pulse output mode (see F03.05 for details), the pulse width of the active level can be controlled by setting the single pulse output time, in order to meet different process or control requirements. Details are given in Fig.

7- and 174 Function Default Function code name Parameter description Unit Attribute code setting F03.17 Single pulse time of Y1 output 0.001 - 30.000 s 0.250 ● F03.19 Single pulse time of R1 output 0.001 - 30.000 s 0.250 ●