EPSON — ^LT

^LT [Name] Shift vertical position [Format] ^LT d [Function]  Sets the amount to adjust the position of the label’s leading edge.  The rendering position is shifted vertically, relative to the label leading edge.  The rendering positions for all fields are shifted downwards the amount specified in Parameter d.  If a minus symbol is included for the value for Parameter d, the rendering positions are shifted upwards for size for the specified value.

 The following figure indicates the positioning of a field without “^LT” set, and field where the downwards shift d was specified with “^LT” (The double white circle indicates the logical origin, and the white circle indicates the field origin). In the example, the logical origin and the label origin are in the same position. x [^LT not set] [After setting adjustment d with ^LT] y Origin (x,y) d ABC x y Origin (x,y) ABC Printable area Printable area [Response] None [Note] If using this command, use it before defining the first field in the label format. The ^JUS command is required to save settings to the non-volatile memory of the printer unit.

Please refer to the “^JU” command section for details. [Reference] Related commands: None [Usage example] An example of sending data that sets the amount to adjust the position of the label’s leading edge, and saves settings to the non-volatile memory of the printer unit is shown below. ^XA ^LT1000 1. Sets the amount to adjust the position of the label’s leading edge to 1000 [dot]. ^JUS 2. Saves the setting to non-volatile memory. ^XZ ESC/Label Command Reference Guide Rev. L Page 175 Parameters Description Definition range d Adjustment for label left edge [dot] -9999 ≤ d ≤ 9999 (Varies depending on the model)