ESC/Label Command Reference Guide Rev. L Page 219 D = Printing direction B/U B: Bidirectional or Unidirectional U:

Unidirectional  None MQ Set peeler control adjustment amount A = Peel position adjustment during automatic application [dot] -9999 to 9999   None B = Peel position adjustment during manual application [dot] -9999 to 9999   None W = Wait time adjustment after peeling label [sec] 0.0 to 60.0 (0.1 sec units)   None MS Printing control adjustment amount C = Wait time adjustment for closing caps [sec] 0.0 to 60.0 (0.1 sec units)   None H = Drying time per head pass [sec] 0.0 to 60.0 (0.1 sec units)   None MT Auto cleaning on designated time S = Enable/disable auto cleaning on designated time E/D E: Enabled D: Disabled  None T = Time to start auto cleaning hh:

mm (hh & mm are number within two digits, hh = 00 to 23, mm = 00 to 59)  None MV Nozzle self-test operation C = Permitted clogged nozzle number 0 to 9999   None I = Self-test interval in printing (number of labels) 0 to 99999999 0: No check during printing   None O = Operation at clogged nozzle detection C/N C: Continue printing N: Notify  None S = Enable/disable nozzle self-test E/D E: Enabled D: Disabled  None A = Cleaning after self-test N/E/D N: Do not execute during printing E: Automatic execution D: Do not execute   None