The Lithium SuperPack NG battery is a drop-in replacement for standard lead-acid batteries in RVs and recreational vehicles. Designed for extended off-grid use, it provides ample capacity to power the complete electrical system, including high-demand appliances. Its form factor and terminal layout ensure easy installation in a wide range of vehicles such as large trucks, SUVs, and RVs. Features Vbatt Bus Audibile Alarm Bluetooth monitoring and control Includes Bluetooth Smart for wireless configuration, monitoring, and firmware updates via the VictronConnect App .

The Instant Readout function displays key data such as state of charge (SoC), battery temperature, warnings, and alarms directly in the device list without the need to connect. Built-in BMS and battery monitor : Integrates cell balancing, protection, and monitoring functions to ensure optimal performance and safety throughout the battery’s service life. External Feedback Signal (EFS) : Provides a battery voltage signal limited to 250 mA. The EFS signal serves as an External Disconnection Signal (EDS) to trigger an event for redundant system protection.

Additionally, the EFS can be configured as an External Charging Signal (ECS), based on the low SoC pre- alarm threshold, to activate a charger start signal. Self-heating function: Maintains the battery temperature above the minimum safe charging limit to ensure reliable operation in cold environments. Two heating modes are available: Charger mode: the heater is powered by the connected charger and activates automatically when the cell temperature drops below 0 °C before charging (default). Auto mode: The battery powers the heater to keep the cells above the minimum safe charging temperature for immediate charging.

This is limited by the battery’s internal energy; if SoC falls below the Low SoC threshold, the heater is disconnected and charging remains unavailable. LED status indication : Two integrated LEDs indicate Bluetooth connectivity, warning and alarm conditions, or firmware update status. On/Off push button : Push button for switching the battery on or off, disabling both charging and discharging functions to allow safe operation and extended storage time. High efficiency : Operating efficiency 93 %. Parallel connection : Supports parallel connection of an unlimited number of batteries to increase total energy capacity.

The total system current should not exceed the maximum current that a single battery can safely interrupt. Configurable discharge floor: Defines a minimum state of charge to avoid excessive discharge while keeping reserve capacity. When the limit is reached, VictronConnect shows a Low SoC alarm and the Allowed to Discharge (ATD) indicator turns off until the state of charge rises above the set threshold. Vbatt+ EFS Output ECS Example connection of the EFS signal output: driving an audible alarm device. Example (12,8 V model) connection of the EFS signal output: driving a visible alarm device. Bus voltage is model- dependent.

Lithium SuperPack 12,8/100 NG Live battery data displayed in VictronConnect Lithium SuperPack 12,8/200 NG & 25,6/100 NG Lithium SuperPack 25,6/200 NG & 51,2/100 NG Victron Energy B.V. | Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Lithium SuperPack NG um SuperPack NG www.victronenergy.com Vbatt Bus Visible Alarm Vbatt+ EFS Output EC

Page 1

Victron Energy B.V. | Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Lithium SuperPack NG 12,8V/100Ah 12,8V/200Ah 25,6V/100Ah 25,6V/200Ah 51,2V/100Ah Part Number BAT512110740 BAT512120740 BAT524110740 BAT524120740 BAT548110740 Nominal voltage 12,8 V 25,6 V 51,2 V Nominal capacity @ 25 °C 1) 100 Ah 200 Ah 100 Ah 200 Ah 100 Ah Nominal energy @ 25°C 1) 1280 Wh 2560 Wh 5120 Wh Capacity loss / Energy loss (per 100 cycles, @25 °C, 100 % DoD):

Round Trip Efficiency 2) 93 % CYCLE LIFE 25 °C (capacity ≥ 80% of nominal) 2) Cycle life 2500 cycles @80 % DoD | 3000 cycles @70 % DoD | 5000 cycles @50 % DoD DISCHARGING Recommended discharge current 50 A 100 A 50 A 100 A 50 A (continuous use) Max continuous discharge current 7) 200 A 400 A 200 A 400 A 200 A End of discharge voltage 11,2 V 22,4 V 44,8 V Internal resistance 2 mΩ 1 mΩ 4 mΩ 2 mΩ 8 mΩ CHARGING Recommended charging voltage 14 V 28 V 56 V Float voltage 13,5 V 27 V 54 V Charging voltage range [13,5 - 14,2] V [27 - 28,4] V [54V - 56,8] V Recommended charging current 30 A 60 A 30 A 60 A 30 A Max continuous charging current7) 100 A 200 A 100 A 200 A 100 A FEATURES Hardware protection / Short circuit above 800 A System Max Current Software protections Overvoltage, Undervoltage, Overtemperature, Undertemperature, Overcurrent Wired Communication External Feedback Signal (EFS) Bluetooth Yes, VictronConnect App User Interface Push button (On/Off), BLE LED, Error LED Self-heating max power 65 W 130 W 260 W OPERATING CONDITIONS Parallel configuration Yes, unlimited energy expansion, with power expansion limited to the system’s maximum current Series configuration No Operating temperature Charge7) and discharge:

-30 °C to +60 °C Humidity Operating Range (non condensing) Storage temperature Recommended [10 - 35] °C Expanded [-40 to +65] °C3) Max storage time @ 25°C 1 year with at least initial remaining SoC>50 % Protection class IP65 MOUNTING Power connection (threaded insert) M8 female 20 mm including nut screws Mounting options Upright and on its long side, maintain flat horizontal support Dimensions [LxWxH] (mm)4) 273 x 173 x 1735) 466 x 198 x 173 871 x 198 x 173 Weight (kg) 10,7 20,5 41 STANDARDS Safety Cells: IEC62619 | UL1973 | UL 9540A Battery:

IEC62619 (pending) EMC EN 61000-6-3, EN 61000-6-2 Performance IEC62620 (pending) Transportation UN38.3 Automotive ECE R10-7 Notes 1) Discharge current ≤1C 2)25 °C and 0.5C cycling 3) Performances might be reduced 4) Additional height of 15 mm for terminal screws 5) Compatible with BCI Group 49 dimensions 1) Discharge current ≤1C 6) Below 0 °C, charging is suspended while the internal self-heating 2)25 °C and 0.5C cycling function warms the cells and automatically resumes once a safe 3) Performances might be reduced charging temperature is reached.

4) Additional height of 15 mm for terminal screws 7) At 25 °C ambient and 100% SoC, 2C can be sustained for 5) Compatible with BCI Group 49 dimensions approximately 10 minutes. The actual duration depends on temperature and voltage protection limits. Above this, overcurrent protection is triggered within 5 seconds.