4-2 Function Mode 4 Functions 4-104 Register No. Function name Parameter No. R/W Function Monitor or data range Resolution 1153h Output terminal P1 ON delay C144 R/W 0 to 1000 0.1 [s] 1154h Output terminal P1 OFF delay C145 R/W 0 to 1000 1157h Relay output ON delay C148 R/W 0 to 1000 1158h Relay output OFF delay C149 R/W 0 to 1000 1165h Motor capacity selection H003 R/W 00: 0.2/02: 0.4/04: 0.75/ 06: 1.5/07: 2.2/09: 3.7/ 11: 5.5/12: 7.5 ⎯ 1541h 2nd motor capacity selection H203 R/W 00: 0.2/02: 0.4/04: 0.75/ 06: 1.5/07: 2.2/09: 3.7/ 11: 5.5/12:
7.5 ⎯ 1166h Motor pole number selection H004 R/W 2/4/6/8 1 [pole] 1542h 2nd motor pole number selection H204 R/W 2/4/6/8 1 [pole] 1168h Stabilization parameter H006 R/W 0. to 255. 1. [%] 1544h 2nd stabilization parameter H206 R/W 0. to 255. 1. [%] 0900h Enter command ⎯ W Indefinite value ⎯