User Manual of EM730 Series Inverter 121 ACR-T1 F14.50 Torque current proportional gain ACR-P2 0.00 ~ 100.00 0.50 ● 0x0E32 F14.51 Torque current integral time constant ACR-T2 0.00 ~ 600.00 0.00: no integral ms 10.00 ● 0x0E33 F14.52 Stiffness coefficient of speed loop of motor 2 0~20 12 ● 0x0E34 F14.53 SVC zero-frequency processing 0: braking 1: not processed 2: seal the tube 2 〇 0x0E35 F14.54 SVC zero-frequency braking current 50.0 ~ 400.0 (100.0 is the no-load current of the motor) % 100.0 〇 0x0E36 F14.56 Voltage feedforward gain 0 ~ 100 % 0 ● 0x0E38 F14.57 Flux weakening control options 0: invalid 1: direct calculation 2:
automatic adjustment 2 〇 0x0E39 F14.58 Flux weakening voltage 70.00 ~ 100.00 % 95.00 ● 0x0E3A F14.59 Maximum field weakening current of synchronous motor 0.0 ~ 150.0 (100.0 is the rated current of the motor) % 100.0 ● 0x0E3B F14.60 Proportional gain of flux weakening regulator 0.00 ~ 10.00 0.50 ● 0x0E3C F14.61 Integral time of flux weakening regulator 0.01 ~ 60.00 s 2.00 ● 0x0E3D F14.62 MTPA control option of synchronous 0: invalid 1: valid 0 〇 0x0E3E