User Manual of EM730 Series Inverter Note that the acceleration and deceleration time is in 0.01 s, 0.1 s or 1s, depending on the F15.13. The allowable maximum frequency of the inverter is represented by Fmax. The Fmax range is from 20.00 to 600.00Hz. F00.17=0: set by F00.18 The upper frequency limit is set by F00.18. F00.17=1:AI1 F00.17=2:AI2 The upper frequency limit depends on AI (percentage) * F00.18. meaning. 100.00% is the percentage relative to the set value of F00.18 (upper frequency limit). For the details of AI1 and AI2, refer to the F00.04 description. They have the same F00.17=5: High-frequency pulse input (X5) The upper frequency limit depends on HDI (percentage) * F00.18.
meaning. 100.00% is the percentage relative to F00.18 (maximum frequency). For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same F00.17=6 or 7: communication setting 161 Function code Function code name Parameter description Unit Default setting Attribute mailing address F00.16 Maximum frequency 1.00~600.00 Hz 50.00 〇 0x0010 Function code Function code name Parameter description Unit Default setting Attribute mailing address F00.17 Options of upper frequency limit control 0: set by F00.18 1: AI1 2: AI2 3: reserved 4: reserved 5: high frequency pulse input (X5) 6: percent setting of upper limit frequency communication 7:
direct setting of upper limit frequency communication 0 〇 0x0011 F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● 0x0012 F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● 0x0013