sinee — Chapter 11 Function Code Table

User Manual of EM760 High-Performance Inverter 305 F07.20 Action option 2 after failure E28 E27 E25 E23 0000 O 0x0714 1: stop according to stop 0: free stop mode F07.21 Options of load loss protection 0: Invalid 1: valid 0 ● 0x0715 F07.22 Load loss detection level 0.0~100.0 % 20.0 ● 0x0716 F07.23 Load loss detection time 0.0~60.0 s 1.0 ● 0x0717 F07.24 Options of load loss protection action 1: stop according to stop 0: free stop mode 1 O 0x0718 F07.25 Motor overspeed detection level 0.0-50.0 (reference: maximum frequency F00.16) % 20.0 ● 0x0719 F07.26 Motor overspeed detection time 0.0-60.0, 0.0: disable motor overspeed protection s 1.0 ● 0x071A F07.27 AVR function 0: Invalid 1:

valid % 1 O 0x071B F07.28 Stall fault detection time 0.0-6000.0 (0.0: no stall fault detection) s 0.0 O 0x071C F07.29 Stall control intensity 0~100 % 20 O 0x071D F07.30 Instantaneous stop/no-stop deceleration time 0.00~300.00 S 20.00 O 0x071E F07.32 Options of retries after failure 2 E10 E1 3 E1 5 E 1 6 * E19 E20 * 11111111 O 0x0720 0: allow retry after 1: disable retry after failure failure F07.34 Encoder disconnection detection percentage 0~150.0 % 100.0 O 0x0722 F07.35 Protection shield 2 * * * * * E15 E18 E81 000 O 0x0723 0: valid protection 1: shielded protection F07.36 Options of retries after failure 3 * * * * * * E09 E17 11 O 0x0724 0: allow retry after 1:

disable retry after failure failure F07.37 Initial voltage for saving upon power disconnection 60.0~F07.38 % 76.0 O 0x0725 F07.38 Electrification voltage reading and determination F07.37~100.0 % 86.0 O 0x0726