airtech · 4 стр.

Actuator Installation.2000.04-30-10 (EN)

Оригинальное название: Actuator Installation.2000.04-30-10

Читать онлайн

Похожие инструкции

Содержание

Текст документа

Sheets and Views

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions INSTALLATION Installation of Airtech Products Durastroke pneumatic actuator is a simple three-step process; Mounting of the actuator & attachment to load, connection of air line and connection of the control signal. Before starting installation, inspect the actuator and contents of the shipping carton to ensure all required parts are present. Check the following: • Ensure the positioner is firmly secured to the actuator body. • Clevis is present at the end of travel stem? • The following hardware kit was included: 1. Five (5) 3/8-16 x 1 Ѕ” long bolts 2. Four (4) 3/8” lock washers 3.

One (1) 3/8-16 locking nut A) Mounting The Actuator: 1. The actuator can be mounted in either a vertical or horizontal position. 2. The actuator is supplied with four (4) 3/8”-16 bolt-holes in the bottom plate for attachment to a mounting plate or bracket. 3. A hole at least 13/16” (but not larger than 1” diameter) must be provided in the center of the actuator mounting bolthole pattern for penetration of the actuator travel stem and clevis. 4. Attach the actuator to the mounting bracket with the four supplied 3/8”-16 x 1Ѕ ” bolts and lock washers. In a rotating pattern, tighten each to 16 Ft-Lbs torque. 5. DO NOT ATTACH THE ACTUATOR TO THE TORQUE TUBE LEVER ARM YET. B) Air Line Connections:

1. Blow out all piping before connections are made to prevent dirt, chips, etc from entering the positioner. Ensure all air entering the positioner and actuator is clean, dry and oil free. Failure to do so increases the possibility of operational problems and/or deviation from specified performance. 2. Locate the 1/4” NPT ports on the Fisher DVC Positioner. 3. Install a 1/4” threaded adapter in the air inlet port. Use Teflon tape or a non-hardening sealant on the male threads of connectors. 4. Connect 1/4” or 3/8” air line to the supply port on the positioner. 125 psig is the suggested maximum total air pressure in this line. C) Control Signal Connection: 1.

Locate the 1/2” NPT port for the conduit connection and install male adapter. 2. Connect conduit and thread wiring into transducer connection terminals 3. Connect leads for control signal to corresponding terminals in Positioner. 4. Securely reinstall cap. 1550 S. 81 st W. Avenue • Tulsa, OK 74127 Office: 918-241-0264 • Fax: 918-241-0270 • www.airtechproducts.com

Стр. 1

Sheets and Views

Durastroke 2000 Pneumatic Actuator Installation Instructions Page 2 of 3 D) Connecting The Linkage: 1. In most cases**, the torque tube lever arm will be preset at the factory to drive the louver either “Fail Open” or “Fail Closed” upon loss of air and / or actuator retraction. As a result, connection of the linkage will be a simple matter of manually situating the louver blades and actuator stem to the correct position and then attaching the control link to the clevis (at the base of the actuator stem) and finally to the torque tube lever arm. To determine how the actuator and louver blades should be positioned, please note the following instructions: a.

“Fail Open” Louvers • Stroke actuator to fully extended and manually set louver to fully closed position before connecting louver lever arm & link to actuator clevis. b. “Fail Closed” Louvers • Ensure actuator is completely retracted and manually set louvers to fully closed position before connecting louver lever arm & link to actuator clevis. 2. When all sections are installed and connected, stroke the actuator several times to ensure it moves the entire louver freely without binding or interference. On very large louvers with multiple sections, inspect to confirm all the sections are fully open and completely closing in unison.

Some adjustment of end links or torque tube clamps may be required to ensure all louver blades open and shut consistently down the entire length or across the entire width of the louver. 3. Check all attachment fasteners to ensure all are properly tightened and completely engaged to the louver flange. 4. If applicable, check all end link connections and torque tube couplers to ensure they are properly tightened and fasteners are completely engaged. **For new orders only when the actuator is purchased in conjunction w/louvers.

Please contact the factory for specific instructions on retrofit or other applications that did not see both the actuator and louver originate as simultaneous/concurrent Airtech orders

Стр. 2

Sheets and Views

Durastroke 2000 Pneumatic Actuator Installation Instructions Page 3 of 3 MAINTENANCE Annual Inspection: 1.

Inspect and verify all mechanical connections • Positioner & mounting bracket bolting to actuator body o Check mounting bracket rigidity o Confirm actuator to mounting bracket bolt tightness • Clevis general condition o Visually inspect overall clevis condition o Confirm fastener between clevis and actuator link is sound • Link to torque tube lever arm o Visually inspect overall link condition o Confirm fastener between link and torque tube lever arm is sound • Positioner attachment to actuator body o Visually inspect positioner for visible cracks or damage o Confirm positioner is securely fastened to actuator body 2.

Inspect and verify all pneumatic and electrical connections • Air connections to positioner o Supply line to threaded adapters o Adapters to positioner • Diaphragm o Confirm pressure is present at Diaphragm § Listen for leaks at stem Repair Kit & Recommended Spare Parts List The following items are recommended as a single actuator repair kit. It is suggested that one repair kit be kept on hand for each 3 actuators on site and in service. Please note a repair & maintenance kit is not offered for the positioner because of the complexity of that particular item. Best practice is simply to replace a non-operational positioner. Item numbers noted below refer to Airtech Products, Inc.

drawing, “Durastroke 2000 Actuator”. Item Number Description 2 Guide Bushing 4 Snap Ring 9 Diaphragm 13 Diaphragm Washer 15 O-Ring 25 Kit, Positioner, Fisher DVC 6010 04-30-10

Стр. 3

Model

ALL UNITS PRODUCED AFTER 15 JULY 2017 DESCRIPTION POSITIONER LINKAGE SAE FLAT WASHER 3/8" TUBING Customer: File #: Date: By: Dwg. Name: SPRING COVER SPRING WASHER 3/4" FLAT WASHER HOUSING SCREW, 3/8 X 1 3/4 HOUSING NUT, 3/8 STD. GASKET POSITIONER, DVC 6200 1/4" NPT FITTING LOCKWASHER COVER PLATE SCREW COVER PLATE MAIN SPRING SPRING ROD 3/8-16 X 1-1/4" SPRING COVER SCREW O-RING CONNECTOR NUT DIAPHRAGM WASHER UPPER HOUSING DIAPHRAGM PLATE 3/4"-16 JAMB NUT DIAPHRAGM 3/8"-16 X 1-1/2" HOUSING SCREW LOCKWASHER HOUSING NUT, ESNA STEM SNAP RING LOWER HOUSING CLEVIS GUIDE BUSHING **SEE NOTE STANDARDS D2000 PARTS DURASTROKE 2000 ACTUATOR PRODUCTS, INC 1550 S., 81ST W. AVE., TULSA, OK.

74127 2/5/2020 PR ITEM QTY. DESCRIPTION 1 1 CLEVIS 2 1 GUIDE BUSHING **SEE NOTE 27 28 26 29 24 3 1 LOWER HOUSING 4 1 SNAP RING 3/8" 5 1 STEM 6 8 HOUSING NUT, ESNA 31 7 11 LOCKWASHER 8 12 3/8"-16 X 1-1/2" HOUSING SCREW 22 9 1 DIAPHRAGM 10 3 3/4"-16 JAMB NUT 30 11 1 DIAPHRAGM PLATE 12 1 UPPER HOUSING 13 1 DIAPHRAGM WASHER 10 14 1 CONNECTOR NUT 21 15 1 O-RING 16 4 3/8-16 X 1-1/4" SPRING COVER SCREW 17 1 SPRING ROD 20 18 1 MAIN SPRING 19 19 1 SPRING COVER 18 20 1 SPRING WASHER 21 1 3/4" FLAT WASHER 16 17 22 1 HOUSING SCREW, 3/8 X 1 3/4 23 1 HOUSING NUT, 3/8 STD.

24 1 GASKET 19 5/8" 25 1 POSITIONER, DVC 6200 26 1 1/4" NPT FITTING 14 27 6 LOCKWASHER 15 12 28 6 COVER PLATE SCREW 29 1 COVER PLATE 13 23 30 1 SAE FLAT WASHER 8 25 31 1 3/8" TUBING 10 11 32 1 POSITIONER LINKAGE 9 5 6 22 ** GUIDE BUSHING WAS ELIMINATED ON 2 3 ALL UNITS PRODUCED AFTER 15 JULY 2017 32 4 1/2" 4 1 PRODUCTS, INC 1550 S., 81ST W. AVE., TULSA, OK. 74127 Dwg. Name: DURASTROKE 2000 ACTUATOR 11 3/4" DIA Date: By: 2/5/2020 PR Customer: File #: STANDARDS D2000 PARTS ITEM QTY.

DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 1 1 1 1 8 11 12 1 3 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 6 6 1 1 1 1 CLEVIS GUIDE BUSHING **SEE NOTE LOWER HOUSING SNAP RING STEM HOUSING NUT, ESNA LOCKWASHER 3/8"-16 X 1-1/2" HOUSING SCREW DIAPHRAGM 3/4"-16 JAMB NUT DIAPHRAGM PLATE UPPER HOUSING DIAPHRAGM WASHER CONNECTOR NUT O-RING 3/8-16 X 1-1/4" SPRING COVER SCREW SPRING ROD MAIN SPRING SPRING COVER SPRING WASHER 3/4" FLAT WASHER HOUSING SCREW, 3/8 X 1 3/4 HOUSING NUT, 3/8 STD. GASKET POSITIONER, DVC 6200 1/4" NPT FITTING LOCKWASHER COVER PLATE SCREW COVER PLATE SAE FLAT WASHER 3/8" TUBING POSITIONER LINKAGE PRODUCTS, INC 1550 S., 81ST W.

AVE., TULSA, OK. 74127 Dwg. Name: DURASTROKE 2000 ACTUATOR Date: 2/5/2020 By: PR Customer: STANDARDS File #: D2000 PARTS 2

Стр. 4