Yanmar — Yanmar Electronic Control System Manual (EN)

3 i5601E Digital Display calibration To calibrate the sender select the “SNDR CAL” line with the up down arrows and then press the right arrow. The screen will change and instruct you to move the drive to the full down position. When you have placed the drive in the full down position press the “DOWN” key. Then move the drive to the full up position and press the “UP” key. This will return you to the Trim screen. Press back again to exit the trim setup. You will then be asked if you wish to save the settings you have just selected. “YES” saves the new settings and “NO” reverts to the existing settings.

TRIM SENDER CALIBRATION SNDR TYPE SM STK SNDR CAL Trim lower units to full down position and press DOWN BACK TRIM SNDR TYPE SM STK SNDR CAL BACK TRIM USER SETTINGS TROLLING TRIM Save Settings? © 2011 Yanmar Marine International • Rev. 2.0 3:34 Yanmar Electronic Control Systems Technical Manual BACK DOWN SENDER CALIBRATION Trim lower units to full up position and press UP UP BACK YES NO BACK