Hengstler Tico Counters Datasheet (EN)
Оригинальное название: Hengstler Tico 772 | 773 | 774 Multifunction Counter Datasheet
Похожие инструкции
Текст документа
email: sales@impulseautomation.co.uk web: www.impulseautomation.co.uk Multifunctional counter tico 772/773/774 tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter … Easy to operate 3 different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48 mm display Input frequency up to 60 kHz Easy installation via plug-in terminals Three presets TECHNICAL DATA Display LCD reflective, Transmissive negative:
white, red or green figures on backlit ground, 2 lines, 6-digit counter readings & presets; leading zero suppression, decimal point (up to 4 decimal places) GENERAL Digit height 1st line 9.3 mm; 2nd line 7.2 mm Supply voltage SELV: 12-30 VDC; reverse polarity protected SELV: 24 VAC, 50/60 Hz ± 10% 115 VAC; 230 VAC, 50/60 Hz ± 10% 100-240 VAC 50/60 Hz ± 10% with switch-mode power supply Current consumption 12-30 VDC 12-30 VDC 24 VAC 115/230 VAC 90 VAC max. 80 mA; including sensor supply with switch-mode power supply Power consumption Duty cycle 100% Overload protection External fuse DC: 0.16 AT (IEC 127); DC: 0.2 AT (UL 198) 24 VAC: 315 mAT; 230 VAC: 32 mAT; 115 VAC:
63 mAT Overload protection External fuse 230 V, 2.5 mAT Relay outputs DC: 0.16 AT (IEC 127); DC: 0.2 AT (UL 198) 24 VAC: 315 mAT 230 VAC: 32 mAT; 115 VAC: 63 mAT Sensor supply Transformer: AC operation: 12-24 VDC (load dependent), max. 50 mA Switch-mode power supply: AC operation: 24 VDC/-5%, max. 115 mA max. capacitive load = 470 µF Data storage Non-volatile memory >10 years Electrical connection Plug-in screw-type connections/terminals Wire cross-section 1-1.5 mmІ with wire-end sleeves Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.
The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC77X Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 22-10-19 1 of 7
Multifunctional counter tico 772/773/774 tico 772/773/774 Amplitude threshold 8 V or 4 V at TTL level, Amplitude max. 40 VDC Active edge Programmable positive for PNP input, negative for NPN input Input resistance Approx. 10 kOhm Count frequency Max. 60 kHz; 30 Hz attenuated max. 20 kHz; 30 Hz attenuated in TTL operation Application input max. 6 kHz/30Hz attenuated To prevent the maximum input frequency of 60 kHz being exceeded, the following maximum input frequencies apply: Phase discriminator, single evaluation: A and B, each 30 kHz (20 kHz) TTL Phase discriminator, double evaluation: A and B, each 30 kHz (20 kHz) TTL Phase discriminator, quad evaluation:
A and B, each 15 kHz (15 kHz) TTL Single-channel metering & directional input: input A 60 kHz (20 kHz) TTL Differential metering, totalizing: input A + B 60 kHz (20 kHz) TTL If the application input is also used as a metering input: Single-channel metering & directional input: input A + app. input 60 kHz (20 kHz) TTL Differential metering, totalizing: input A + B + app. input 60 kHz (20 kHz) TTL ->refer to graph on Page 5 Pulse wave shape Any (at max. frequency, square 1:1) Pulse duration min. 17 ms (30 Hz); 8 µs (60 kHz) Prescaler 0.0001-99.9999 Reset Manual reset via keyboard, external static or dynamic reset, min. pulse length 5 ms, automatic reset after reaching Preset 2.
No pulse losses at max. counter frequency due to automatic reset function. Via programmable application input and programmable power-on reset Set function Setting to Preset 0 (independent of reset) Display and -999,999 to +999,999 preset range Alarm signal Display flashes when preset 0, 1 or 2 is active Signal times 0.01 s to 599.99 s or bistable programming; tolerance ± 10 ms; active on or off Relay Change-over contact max.: 250 VAC/30 VDC/5 A (Presets 1 and 2) Change-over contact min.: 5 VAC/5 VDC/10 mA; delay Transistor output PNP output 12-30 VDC, max. 50 mA for DC supply (Presets 1 + 2) 12-24 VDC, max. 30 mA for AC supply 24 VDC, max.
50 mA for AC supply with switch- mode power supply Application output PNP output 12-30 VDC, max. 20 mA for DC supply 12-24 VDC, max. 20 mA for AC supply 24 VDC, max. 20 mA for AC supply with switch- mode power supply AC transformer only Combined current load of outputs (sensor 12-24 VDC, Out1, Out2, app. output) must not exceed 65 mA. Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC77X Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 22-10-19 2 of 7
Multifunctional counter tico 772/773/774 tico 772/773/774 COUNTER Counter mode Unidirectional; adding or subtracting; directional input; Input A,B Differential operation, add/sub; totalizing add/add; phase discriminator single, double or quadruple evaluation Control input Reset, gate Preselect modes Absolute or trailing, range signal/ limit values (signal 1 P 2) Application Output: prescaler out, preset 0 out, direction out input/output Input:
additional counter input add/sub, reset, set, gate, keylock, hold, teach in BATCH COUNTER Mode Batch counter with preset or 2nd totalizer with preset SHIFT COUNTER Counter mode Differential counting add/sub, totalizing add/add of operation TACHOMETER Measuring principle Period (cycle) measurement (1/tau) Time base 1/min or 1/s Min. frequency 1 Hz or 0.1 Hz Limit values 2 alarms with programmable startup suppression + 1 additional upper limit value on the application output Tachometer Unidirectional add/sub; directional input mode of operation Differential add/sub; totalizing add/add; Phase discriminator single, double or quadruple evaluation A/B or (A-B)/A % Application Output:
Preselect 0 out, direction out input/output Input: Additional counter input add/sub, keylock, hold, teach in Accuracy of the Time base: ± 30 ppm tachometer function Measuring principle: cycle duration measurement Measuring time: min. 0.5s/max. 1s or 10s Measuring resolution: 0.4µs ( Display resolution: 4 decimal places, 1 digit = 100 ppm Overall tolerance = displayed resolution + tolerance of timebase = 130 ppm TIMER Measuring principle Pulse-width or cycle duration measurement Start input A + Stop input B; Start/Stop key Time base Programmable in sec, min, h or hh.mm.ss Resolution 1; 0.1; 0.01; 0.001; 0.0001 Function Single-pulse or cumulative measurement Application Output:
preset 0 out, input/output Input: additional run, stop, reset, set, keylock, hold, teach in Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC77X Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 22-10-19 3 of 7
Multifunctional counter tico 772/773/774 tico 772/773/774 Accuracy Time base: ± 30 ppm of the timer Start/Stop-point in time: 16 µs/16 ms (not damped/damped) Resolution: 100 µs = 100 ppm Overall tolerance = Displayed resolution + tolerance of timebase = 130 ppm ENVIRONMENTAL REGULATIONS, SAFETY PROVISIONS Safety provisions EN 61 010-1/IEC 61010-1 Protection class II; EN 61010-1/IEC 61010-1 EMC interference EN 61326-1 industrial environment** compatibility Pollution degree V 2, EN 50178 EMC emissions EN 61326-1 Class B** Ambient temperature 0°-50°C EN 60 068-2-1/2 Storage temperature -20° to +65°C EN 60 068-2-1/2 Climate 40°C/93% rel. humidy class 4K4H, EN 60 068-2-78 25-50°C/93% rel.
humidity cyclical, EN 60 068-2-38 Ingress protection IP 65 front; EN 60529 IP 20 terminals Vibration resistance 10 m/sІ (10 to 150 Hz); IEC 60 068-2-6 Shock resistance 100 m/sІ (18 ms); IEC 60 068-2-27 Resistance Front film to DIN 42 115-2 to chemicals Approvals UL, CSA (pending) RoHS Compliant PHYSICAL DATA Installation Front-panel installation with tenter (frame) Front panel thickness max. 11 mm Dimensions In accordance with DIN 43700, 48 mm x 48 mm x 118 mm, installation depth 110 mm Front-panel cutout 45 mm x 45 mm + 0.3 mm Weight Approx. 200 g ** For cable lengths >30 m, connection to DC supply and input level TTL, additional protective circuits will be necessary.
Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC77X Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 22-10-19 4 of 7