Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk RM090 Series Linear Solenoid Push and/or Pull Type Heavy duty linear solenoid RM 090 Weight: Complete solenoid: appr. 4500 g Armature: appr. 800 g Standard: Voltage: 24 V DC Flying leads: 20 cm Insulation class: F (max. permissible temperature = 155 ° C) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 25 mm. 1) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice) Document LNSRM9/15 Revision 00 2 1000 2000 %ED 500 700 Force vs.
Stroke diagram F = f (s) 25 15 5 200 W = horizontal characteristic 100 40 Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature F/N 50 100 20 stroke s = 0 corresponds to armature in fully home position 10 0 5 10 15 20 25 30 s/mm Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. 100 40 25 15 5 % Perm.
duty Cycle (ED)1) 51 102 194 303 748 W Nominal coil power Pn 85 38 ms Actuation time (ED)
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk RM090 Series Linear Solenoid Push and/or Pull Type M12 Ш55 80 5 5 66 95 94 12 60 251 Dimensions given with armature in fully home position Dimensions given with armature in fully home position Direction of stroke Direction of stroke Ш9,5 Ш90 100 19 30 M12 80 5 5 55 Document LNSRM9/25 Revision 00 2 125 124 12 Ш90 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.
The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. without stroke limiter 94 40+1 ~23 11 11 40+1 55 Ø68 Ø52 M 80 with stroke limiter 270 136 Ø55 40+1 11 ~53 40+1 M1 12 2 Ø68 Ø52 M 19 30 100 80
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk RM090 Series Ordering Information 2) See below 3) Opposite to electrical connection 4) Same side as electrical connection 5) Available with stroke limit only 6) For plug-in socket 6.3 DIN 46247 and plug 200 +15 Z801 and Z811 Coil terminals N F Examples of design types: Direction of stroke Document LNSRM9/35 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.
The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. RM 090 – W – O R O R – N – 24 V DC 100 % ED Ord er specifications RM Line ar solenoid series 090 Des ign type ø mm W Hor izontal frontal force vs. stroke output Des cription2) O Stroke limit without H with R Plunger right hand side3) B both sides O Flange without R right hand side3) L left hand side4) O Gaiter without R right hand side3) L left hand side4) 5) B both sides5) F Coi l terminals Flying leads (20 cm standard length) N plug-in socket connection6) 24 Op erating voltage 24 V DC 205 205 V DC (connected to 230 V AC with SI- bridge rectifier) 100 % ED Per m.
duty cycle under air cooled conditions (LK) ca.12 ca.12
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk RM090 Series Accessories 41,0 10,0 Plug-in socket Z801 Screw joint PG 9 for lead diameter 4.5 - 7 mm 5,5 34,2 Plug-in socket Z811 Screw joint PG 11 for lead diameter 6 - 9 mm Plug-in socket with built in Si-bridge rectifier (30,5) Flange (Mounting screws are part of the shipment) ШJ ШG ШЕ ШF ШD Order specification C B H Document LNSRM9/45 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.
The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Ø 19,0 ØI ØL K A ØI ØL K A ØL K Order Dimensio ns (mm) Dimensi ons (mm) Order number Type A B C D E F G H I J K L Type number Z 843 RM 090 100,0 12,0 17,0 52,0 43,0 52,0 90,5 1,0 9 ,5 6,4 80,0 68,0 RM 090 Z 843