Текст документа
0. Safety Guidelines 1 ............................................................................................................ 1. Product Description ........................................................................................................ ................................................................................................................ ..................................................................................................................... 1 1.1 Description 1 1.2 Features 1 2. Order Information .........................................................................................................
1 1 2.1 Output Configuration Guide ....................................................................................... ....................................................................................... .............................................................................................................. 1 2.2 Notes on Output Configuration 3 3. Mechanical Specification and Input/Output Terminals 2.3 Label Marking 3 3.1 Mechanism of Front-End ................................................................................................ ..............................................
3 3.2 Mechanism of Output Modules ........................................................................................ 3 4 . Product Specifications ................................................................................................. 4 4.1 Front-End Specifications ............................................................................................... 6 4.2 Single Output Module Specification ................................................................................. ................................................................................... 6 7 4.3 Dual Output Module Specification 8 5.
Functions ....................................................................................................................... 9 5.1 Input Voltage ................................................................................................................ 9 5.2 Inrush Current Limiting .................................................................................................. 9 5.3 Output Voltage / Current Adjustment ................................................................................ 9 5.4 Short-Circuit and Over Current Protection 5.5 Over Voltage Protection ........................................................................
................................................................................................. 10 5 . 6 Over Temperature Protection and T-Alarm ........................................................................ ...................................................................................................... ............................................................................................................. 10 10 5.7 Fan-Lock Protection 10 5.8 Remote Control 10 5.9 Output Module Remote Sense .........................................................................................
........................................................................................................... 12 5.10 Auxiliary Power .................................................................................... ....................................................................................................... ......................................................................................................... ....................................................................................................................... 12 5.11 DC-OK Signal and LED Indicator 5.12 Parallel Operation 13 5.13 Series Operation 14 14 6.
Assembly 15 6.1 Assembly Procedures .................................................................................................... ........................................................................................................ 15 6.2 Assembly Example 18 6.3 Assembly Suggestion .................................................................................................... 19 7. Notes on Operation ....................................................................................................... 20 7.1 Front-End Mounting 7.2 Output Wiring Guidelines ...............................................................................................
..................................................................................................................... ...................................................................................................... 20 7.3 De-rating 20 7.4 High Potential ............................................................................................................... 20 21 7.5 Warranty ...................................................................................................................... 21 8 . Environmental declaration information ................................................................... 21 A .
Appendix ....................................................................................................................... 22 Mar. 2024 Version 12
Стр. 2
2.1 Output Configuration Guide
NMP650,1K2 Family Instruction Manual 0. Safety Guidelines Risk of electrical shock and energy hazard, please do not remove the case from the power supply unit. The output module configurations should only be changed by a trained professional. This unit is cooled by forced-air cooling, so fans and ventilation holes must be kept free from any obstructions. A minimum clearance Please do not perform hot-swap of modules during operation, otherwise there will be risk of damaging the power supply unit and electrical of 10cm is recommended. Please do not change any components of the unit or make any kind of modifications to the unit.
Please do not install the unit in places with high moisture, high ambient temperature or under direct sunlight. The input voltage range is 100-240Vac (50/60Hz), please do not input voltage that is over or less than 10% of this range. The safety protection level of this unit is Class I. The “Frame Ground” ( ) on the power supply unit must be well connected to PE shock hazard. 1. Product Description (Protective Earth). 1.1 Description NMP is MEAN WELL's new generation intelligent modular power supply, bringing forth the state-of-the-art Front-End and NMS- 240/NMD-240 output module designs.
This family offers output module configurability, intelligent control functions, and 1U low profile form factor. The NMP family also complies with both ITE and medical safety standards, offering the best flexibility for various types of applications. The end user will be able to fully customize the output voltages by choosing single output modules of 5V, 12V, 24V and 48V and dual output of 36V, which have wide voltage range and adjustment capability that fully covers 3~55V.
1.2 Features UL/EN/IEC62368-1 IT safety approval UL/EN60601-1(3rd Edition) Medical safety approval (2x MOPP), 4KVAC Isolation 2018 Taiwan Excellence Award (NMP1K2) Efficiency up to 91% Low leakage current 1U low profile mechanical design Built-in active PFC function Universal AC input/ full range Built-in active current sharing and parallel control capabilities Constant current level programmable (PC, ) NMS 240 only - Output voltage programmable (PV, ) NMS 240 only - Global or Local ON/OFF control DC-OK signal and LED indicator for output module Remote sense for output module ( ) NMS 240 only - Over-temperature protection and T-Alarm on Front-End Forced air cooling by built-in DC fan(s) with fans speed control function Built-in 5V auxiliary power for both Front-End and NMS-240 modules ( ) NMS 240 only - Protections:
Short circuit/ Overload/ Over voltage/ Over temperature for all output modules 5-years warranty Surge protection levels that meet industrial standard 2. Order Information 2.1 Output Configuration Guide SLOT 4 SLOT 3 SLOT 2 SLOT 1 NMP - SLOT 6 SLOT 5 650/ 1K2 (650W/ 1200W) - 650W (4 SLOTS) 1200W(6 SLOTS) Parallel or option code (See Table 1.) Example: NMP 1K2 C E D H K # - - SLOT 1 O/P: 5V@ 36A SLOT 2 O/P: 12V@ 20A SLOT 3 O/P: 24V@ 10A SLOT 5 Blank slot (with BLANK-NMS240) SLOT 4 O/P: 48V@ 5A SLOT 6 O/P: V1 30V@ 5A V2 30V@ 5A (Combined 240W max.) 1
Стр. 3
2.1 Output Configuration Guide
Table 1.
Parallel or option code Code 00~31 for NMP1K2 Code 00, 01, 02, 03, 06, 07, 10, 16 for NMP650/NMP1K2 2 Code SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 00 ----- ----- ----- ----- ----- ----- 01 ◎ ◎ ----- ----- ----- ----- 02 ----- ◎ ◎ ----- ----- ----- 03 ----- ----- ◎ ◎ ----- ----- 04 ----- ----- ----- ◎ ◎ ----- 05 ----- ----- ----- ----- ◎ ◎ 06 ◎ ◎ ◎ ----- ----- ----- 07 ----- ◎ ◎ ◎ ----- ----- 08 ----- ----- ◎ ◎ ◎ ----- 09 ----- ----- ----- ◎ ◎ ◎ 10 ◎ ◎ ◎ ◎ ----- ----- 11 ----- ◎ ◎ ◎ ◎ ----- 12 ----- ----- ◎ ◎ ◎ ◎ 13 ◎ ◎ ◎ ◎ ◎ ----- 14 ----- ◎ ◎ ◎ ◎ ◎ 15 ◎ ◎ ◎ ◎ ◎ ◎ 16 ◎ ◎ ◎ ◎ ----- ----- 17 ----- ◎ ◎ ◎ ◎ ----- 18 ----- ----- ◎ ◎ ◎ ◎ 19 ◎ ◎ ----- ◎ ◎ ----- 20 ◎ ◎ ----- ----- ◎ ◎ 21 ----- ◎ ◎ ----- ◎ ◎ 22 ◎ ◎ ◎ ◎ ◎ ◎ 23 ◎ ◎ ◎ ◎ ◎ ----- 24 ◎ ◎ ----- ◎ ◎ ◎ 25 ----- ◎ ◎ ◎ ◎ ◎ 26 ◎ ◎ ◎ ◎ ◎ ----- 27 ◎ ◎ ◎ ----- ◎ ◎ 28 ----- ◎ ◎ ◎ ◎ ◎ 29 ◎ ◎ ◎ ◎ ◎ ◎ 30 ◎ ◎ ◎ ◎ ◎ ◎ 31 ◎ ◎ ◎ ◎ ◎ ◎
Стр. 4
3.1 Mechanism of Front-End
Modules to be in parallel or series connection should be placed in adjacent slots. The combined operation output power of all modules must be less than the Front-End's rated maximum output power: 1200W for 2.2 Notes on Output Configuration NMP1K2 and 650W for NMP650. 2.3 Label Marking , , 10 www. ID 2000000000 Bauar Sicherheit od be egel ge ma wac g o s tuv.com t gepruft 10 www.
ID 2000000000 Bauar Sicherheit od be egel ge ma wac g o s tuv.com t gepruft 2 3 4 SLOT1 SLOT2 SLOT2 SLOT3 SLOT3 SLOT4 5 6 MADE IN TAIWAN +V CN81 2 3 4 SLOT1 MADE IN TAIWAN +V CN81 + + 5V 5V 12V 12V 20A 20A - - SLOT1 SLOT1 + + 36A 36A - - + + 24V 24V 10A 10A - - + + 48V 48V 5A 5A - - + + 30V 30V 30V 30V 5A 5A 5A 5A SLOT5 SLOT6 SLOT4 - - - - + + +V1 +V1 +V2 +V2 CN82 CN82 Figure 2-1. NMP650 Product Label Figure 2-2. NMP1K2 Product Label 1 Serial Number. 2 Input Rating. 3 Maximum Output Rating. Safety Marks. 4 5 Output Encoding. 6 Output Module Terminal Diagram. 3. Mechanical Specifications and Input/Output Terminals 3.1 Mechanism of Front-End NMP1K2 Case No.260A Unit:mm 250 14 max.
219.1 6.1 10 max. 20.5 +V 8.6 11 4-M4(Both Sides) L=4 -V 41 2 2 92 122 CN32 6 5 13.2 20 20 20 20 20 13.8 2 1 80 1 4-M4 L=4 1 Air flow direction 127 1 2 TB1 9.5 8 3 1 1 3 3.5
Стр. 5