Pneumatic Mini Timer · 2 стр.

Pneumatic Timer Instructions 51 and 57 Series | Impulse Automation (EN)

Оригинальное название: Pneumatic Timer Instructions 51 and 57 Series

Читать онлайн

Текст документа

Pneumatic Mini Timer Instructions Pneumatic Mini Timer Instructions Continued For 5 1.020.03.00/51.020.30.00/51.020.33.00/51.020.34.00/51.021.03.00/51.021.30.00 + ATEX Variants Technical Data Smooth functionality and reliable timing can only be guaranteed if the instructions within this document are strictly followed. 2 to 6 bar 1.2 +/- 0.4 bar 0.3 +/- 0.2 bar Reset time: Min. 200 ms Service Life: Vibration resistance: Shock resistance: IP rating: Temperature range: Pressure range: Pick-up pressure: Drop-out pressure:

The miniature pneumatic timer is an adjustable timing device that offers excellent repeat timing and setting accuracy, typically used as an ON delay or an OFF delay function to signal other valves or devices within purely pneumatic systems. Setting the pneumatic timer is achieved by adjusting the front rotary knob to the desired set point; there are two vertical scales; one indicates the setting time and the other the time remaining in the cycle. 5 million cycles 30 m/s (10-500 Hz) 400 m/s (during 5 ms) IP40 when connected. IP55 when using a polycarbonate transparent cover. 0°C to +60°C Medium temperature: Maximum 30°C (compressed air temperature). Display: Housing: • ON delay timers.

The timing sequence begins by applying compressed air to port 1. On reaching a preset value, port 2 connects to port 1. The output at port 2 remains on whilst air to port 1 is connected. Air removal from port 1 resets the preset timing value, and the output from port 2 disconnects from port 1. • OFF delay timers. Port 2 to 1 is connected. The timing sequence begins by applying compressed air to port 12. On reaching a preset value, port 2 closes. The output at port 2 remains closed whilst air to port 12 is connected. Air removal from port 12 resets the preset timing value, and port 2 to 1 reconnects. Digit roll Plastic material.

Product S election Mini timers can be built into the front panel of equipment. Panel cut-out: 45mm (+0.6) x 22.2mm (+0.3) and secured in place with a fixing clip. Please ensure the panel cut-out is large enough that the timer is not placed under mechanical tension or strain when built in. Additionally, a panel frame, part number 1499512, provides a wider aperture giving a professional looking finish to panels. Panel frames are used individually or with protective covers. Din-rail mountings allow the timer to be mounted inside a panel for additional protection and also to prevent tampering. Installation & Mounting Pneumatic Connections Mini timers are provided with threaded M5 connections.

Please ensure a tight seal is provided by fully inserting tubing and by tightening threads sufficiently providing a proper seal. We recommend the use of self-sealing fittings, this is a fitting that incorporates an NBR sealing ring. We do not recommend the use of thread sealing compounds. Due to the close proximity of ports we recommend a cylindrical shape fitting. Accessories 50010N-04-05 M5 to 4mm o/d tube 50010N-06-05 M5 to 6mm o/d tube Timing Reset Automatic reset by air removal. ON delay timers by removal of air to port 1. OFF delay timers by removal of air to port 12. ATEX Not suitable for external or harsh environments. Protect from corrosion.

General advice is to house within an enclosure or control panel with suitable protection rating or use a protective cover. See accessories. Environment As well as standard timing devices which are intrinsically safe, we offer ATEX fully certified, CE-marked pneumatic timing products that comply with the ATEX directives for use within category M2 and group II, zones 1 and 21. See product selection. ATEX timing products (57.020.03.EX, 57.020.30.EX, 57.020.33.EX, 57.020.34.EX, 57.021.03.EX, 57.021.30.EX) conform to the following standards: Air Quality Clean, dry and oil free air to instrument quality standards.

Please note that at low operating/ambient temperatures air filters alone will not be sufficient. Air dryers are recommended to achieve low moisture dew point. Exhaust Compressed air will exhaust from this device as part of the operating sequence. This could be sufficient volume and pressure to create risk or introduce problems within an enclosure. Our declaration of conformity can be downloaded from https://www.impulseautomation.co.uk/downloads Safety & Warnings Warning: ATEX products should never be used in Zone 0 or Zone 20, as defined in IEC 60079-10-1:2015 and IEC 60079-10-2:2015.

Only competent qualified persons should install, mount, attach hoses, initially operate, maintain, test and disassemble this product. Never disconnect power lines or service the device when the system is powered. This product should only be used for its intended purpose and within the limits and conditions as described. When cleaning or servicing the product, to avoid electrostatic discharges, use a damp anti-static cloth. The system builder is responsible for ensuring that the final system meets any hazardous zone, EX or ATEX requirements. Disclaimer Impulse Automation Limited accepts no responsibility for the application of this product. email: sales@impulseautomation.co.uk website:

www.impulseautomation.co.uk Page 3/4 Page 2/4 Impulse Automation Limited United Kingdom Company Registration 665193 Order Code (No ATEX) Order Code (+ ATEX) Function & Time Range Repeatability Setting Accuracy 51.020.33.00 57.020.33.EX ON delay - 0.2 to 3 seconds +/- 0.1 s +/- 0.3 s 51.020.03.00 57.020.03.EX ON delay - 2 to 30 seconds +/- 0.3 s +/- 0.6 s 51.020.34.00 57.020.34.EX ON delay - 8 to 120 seconds +/- 1.2 s +/- 3.0 s 51.020.30.00 57.020.30.EX ON delay - 20 to 300 seconds +/- 3.0 s +/- 6.0 s 51.021.03.00 57.021.03.EX OFF delay - 2 to 30 seconds +/- 0.3 s +/- 0.6 s 51.021.30.00 57.021.30.EX OFF delay - 20 to 300 seconds +/- 3.0 s +/- 6.0 s Order Code Description Comments 51.031.00.00 Din-rail mounting adaptor with M5 ports Not compatible with OFF delay timers 51.031.00.01 Din-rail mounting adaptor with 4mm push-in ports Not compatible with OFF delay timers 1499512 Panel frame 52mm x 52mm cut-out Provided with 2 x M4 screws 1405613 Hinged cover with rotary knob Select 1499512 with this accessory 1405614 Hinged cover with lock and key Select 1499512 with this accessory Standard Classification Issued EN ISO 80079-36 EN ISO 80079-37 Ex II 2G Ex h IIB T4 Gb (0°C ≤ Ta ≤ + 60°C) 2016 Ex II 2D Ex h IIIB T1 20°C Db (0°C ≤ Ta ≤ + 60°C) Ex I M2 Ex h I Mb (0 °C

Стр. 1

21.80 OFF delay timer connections The OFF is delayed. The output valve is positive while timing and negative on timeout. Normally open timing. 11.60 7.10 0 0 7.70 18.20 Instructions 34.20 44.60 The ON is delayed. The output valve is negative while timing and positive on timeout. Normally closed timing. Pneumatic Mini Timer 21.80 ON delay timer connections 11.60 2 1 + ATEX Models 34.20 44.60 t P neumatic Mini Timer Drawings Adjustable fixing clip 57.50 21.80 0.2 to 3 seconds X 0.1 2 to 30 seconds None 8 to 120 seconds X 10 20 to 300 seconds X 10 Mini timer display scaling 0 2.50 10.24 6.40 24 The information shown within these pages is for guidance purposes only.

No liability is accepted for errors or omissions. The designer or user is solely responsible for safely and correctly using the parts, assemblies or equipment described. Please always refer to our website for latest updated instruction information. This instruction manual is not available in other languages 48 Page 4/4 Print on both sides of paper. Flip on short edge. Document INS003 Revision 1