Chapter 3: Hardware Overview 3.3 20569-000 Rev. A EM2100 Installation Guide 13 The EM2100 rear panel connectors and features are described in the following table. Table 3-2. Description of EM2100 Rear Panel Connectors and Features Callout Description 1 Four USB ports. Service use only. 2 SVGA Video DB15 port. Service use only. 3 Four auto-speed motherboard cooling fans. Fan speed (and noise volume) varies depending on the CPU load and the ambient temperature. 4 Power supply cooling fan. 5 AC power input connector (IEC 60320 C14). 6 Main power input switch. Keep this set to ON (I) during normal operation and use the front power switch to control power.
Refer to Turn EM2100 Power ON and OFF on page 31 for more inform- ation. isplay Panel Information The EM2100 includes an LCD display panel that provides status and other information described in the following table. Table 3-3. EM2100 Status Display Messages Message Description OMRON ROBOTICS AND SAFETY TECHNOLOGIES Standard splash message during power ON. EM2100 STARTING Boot message after power ON. MODE: Configuration mode of the appliance. FLEET MANAGER STANDALONE: Configured as a Standalone Fleet Manager. FLEET MANAGER PAIRED: Configured as a Primary Fleet Manager or a Secondary Fleet Manager. ETH0: ETH1: ETH2: ETH3: Link status of each port. UP: Ethernet link established. DOWN:
Ethernet link not established. ETH1: IPv4 address for the Management Ethernet port and the Fleet Ethernet port.