Victron Energy · Lithium NG · 2 pp.
Victron Energy Lithium NG Battery (12.8V/25.6V/51.2V) — Datasheet
Технические характеристики литий-железофосфатных батарей (LiFePO₄ или LFP) различных номинальных напряжений: 12.8 В, 25.6 В и 51.2 В. Описание функций, включая интегрированный шунт, управление и мониторинг через VictronConnect, характеристики цикла жизни, разряда и заряда.
Related manuals
Document text
12,8 s , 25,6 & 51,2 Volt L i thium NG batterie www.victronenergy.com Victron Energy Lithium NG batteries are Lithium Iron Phosphate ( available in various capacities with nominal voltages of 12.8 V , 25.6 LiFePO₄ V and 51.2 or LFP) batteries V . They can be connected in series, parallel, or a combination of both to create battery banks for system voltages of 12V, 24V, or 48V. A maximum of 50 batteries can be used when configuring a bank with 12V or 24V batteries, while up to 25 batteries can be us energy storage capacity of 192 kW h with 12V batteries, up to 384 kWh with 24V batteries, and 128 ed with 48V batteries. This allows for a maximum kWh with 48V batteries.
25,6 V 200 Ah Lithium NG battery Key features: Integrated shunt The battery data (battery voltage , current and temperature ) are transmitted to the BMS and evaluated there, i.e. to calculate the state of charge, which can then be read out via VictronConnect or a GX communication centre, or to create and issue specific warnings and alarms. Automatic s etup, monitoring and control via VictronConnect App or a GX device and the VRM Portal All battery parameters are managed by the BMS system voltage and the number of batteries in parallel, series and series/parallel connection. automatically . The BMS automatically detects the The BMS ( must be purchased separately.
from now on Lynx Smart BMS NG 500 A/1000 A, further models to follow ) is mandatory and Secured with mounting brackets Monitoring and control take place via VictronConnect communication centre or the VRM Portal . You can view battery parameters such as cell status, (every BMS model has Bluetooth) , a GX cell voltages, battery current and temperature s in real - time. The battery firmware is automatically updated by the BMS. Easy bracket mou n ting M against slipping and tipping over.
ounting brackets make the installation easier and ensure that the battery is optimally secured Increased ingress protection (IP - rating) The Lithium NG batteries are effectively sealed against dust and can withstand low jets, making them suitable for environments where exposure to dust and water is a concern. - pressure water Low self The self - - discharge rate has been significantly improved and is now a maximum of 2 discharge rate % of the battery capacity per month . A low self - discharge rate contributes to the overall performance, longevity, and reliability of the NG batteries .
Lynx Smart BMS NG 500 A & 1000 A Complete overview of all Typical system example with Lithium NG battery and Lynx Smart BMS NG VictronConnect (or a GX battery data via device and VRM)
Our Lithium NG batteries have integrated c ell b alancing and cell monitoring . The cell balancing/monitoring cables can be daisy Battery Managem - chained and must ent System (BMS) be connected to a Battery Management S ystem (BMS). The BM 1. S will: 2. Generate a pre Disconnect or shut down the load whenever the v - alarm whenever the voltage of a battery cell decreases to less than 3 oltage of a battery cell decreases to less than 2 . 0 V. . 8 V. 3. Stop the charging process whenever the voltage of a battery cell increases to more than temperature becomes too high or too low . 3 . 6 V or when th e See the BMS datasheets for more features .
Battery specification VOLTAGE AND CAPACITY LFP- 12,8/100 LFP- LFP- LFP- LFP- LFP- LFP- LFP- 51,2/100 12,8/150 12,8/200 12,8/300 25,6/100 25,6/200 25,6/300 Nominal voltage 12,8 V 12,8 V 12,8 V 12,8 V 25,6 V 25,6 V 25,6 V 51,2 V Nominal capacity @ 25 °C* 100 Ah 150 Ah 200 Ah 300 Ah 100 Ah 200 Ah 300 Ah 100 Ah Nominal energy @ 25 °C* 1280 Wh 1920 Wh 2560 Wh 3840 Wh 2560 Wh 5120 Wh 7680 Wh 5120 Wh Capacity loss (per 100 cycles, @ 25 °C, 100 % DoD): Energy loss (per 100 cycles, @ 25 °C, 100 % DoD):
Round trip efficiency 92 % * Discharge current ≤1C CYCLE LIFE (capacity ≥ 80 % of nominal) 80 % DoD 2500 cycles 70 % DoD 3000 cycles 50 % DoD 5000 cycles DISCHARGE Max continuous 100 A (1C) 150 A (1C) 200 A (1C) 300 A (1C) 100 A (1C) 200 A (1C) 300 A (1C) 100 A (1C) discharge current (C-rate) Max pulse discharge current 10s (C-rate) 200 A (2C) 300 A (2C) 400 A (2C) 600 A (2C) 200 A (2C) 400 A (2C) 600 A (2C) 200 A (2C) End of discharge voltage 11,2 V 22,4 V 44,8 V Internal resistance 2 mΩ 1 mΩ 4 mΩ 2 mΩ 1 mΩ 8 mΩ CHARGE Charge voltage Between 14 V / 28 V / 56 V and 14,4 V / 28,8 V / 56,8 V Float voltage 13,5 V / 27 V 54 V Max continuous charge current (C-rate) 100 A (1C) 150 A (1C) 200 A (1C) 300 A (1C) 100 A (1C) 200 A (1C) 300 A (1C) 100 A (1C) Max pulse charge current 10s (C-rate) 200 A (2C) 225 A (1.5C) 400 A (2C) 450 A (1.5C) 200 A (2C) 400 A (2C) 450 A (1.5C) 200 A (2C) GENERAL BMS-es Lynx Smart BMS NG 500 A / 1000 A (M10 busbars), must be purchased separately Cell measurements Cell voltages and temperatures, battery current Battery BMS interface Male + female cable with M8 circular connector with high -speed digital communication , length 50 cm M8 extension cables are available separately for purchase in various lengths between 1 and 5 meters Alarm feature Pre-alarm contact on BMS Bluetooth In the BMS Max batteries per BMS 50 (up to 384 kWh per BMS 3)) 25 (128 kWh per BMS 3)) Battery firmware updates Battery firmware automatically updated by BMS Repairable Yes (cover can be removed with screws) OPERATING CONDITIONS Operating temperature Discharge:
-20 °C to +50 °C | Charge: +5 °C to +50 °C Storage temperature -45 °C to +70 °C Humidity (non -condensing) Max. 95 % Protection class IP65 MOUNTING Mounting options Strap or mounting brackets (brackets included) Can be placed on their sides Yes2) OTHER Self-discharge rate ≤ 3 % per month @ 25 °C Power connection M8 (threaded inserts and bolts) Dimensions (h x w x d) mm 235 x 197 x 160 205 x 250 x 205 235 x 341 x 160 206 x 447 x 205 235 x 341 x 160 235 x 648 x 162 206 x 841 x 205 235 x 648 x 162 Weight (est.) 9 kg 14 kg 19 kg 29 kg 19 kg 37 kg 52 kg 37 kg STANDARDS Safety Cells: UL1973 UL9540A IEC62619 Cells: UL1973 Cells: UL1973 Cells: UL1973 Cells: UL1973 Cells: UL1973 Cells: UL1973 Cells:
UL1973 UL9540A IEC62619 (all three pending) UL9540A UL9540A UL9540A UL9540A UL9540A UL9540A IEC62619 (all IEC62619 IEC62619 (all IEC62619 IEC62619 IEC62619(all three pending) three pending) three pending) Battery: IEC 62619 (pending) UL 2054 4) Battery: IEC 62619 (pending) Battery: IEC Battery: IEC 62619 (pending) Battery: IEC Battery: IEC Battery: IEC 62619 (pending) Battery:
IEC 62619 (pending) UL 2054 4) 62619 62619 62619 (pending) (pending) (pending) UL 2054 4) UL 2054 4) UL 2054 4) EMC EN 61000-6-3, EN 61000-6-2 Automotive ECE R10-6 Performance IEC 62620 1) When fully charged 2) The lithium battery can be mounted upright and on its side, but not with the battery terminals facing down 3) Up to 5 BMS-es can be paralleled. For more info, please see this announcement . 4) Certified with Lynx BMS NG Victron Energy B.V. | De Paal 35 | 1351 JG Almere |T he Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com